9. IMAGE FUSING
9.1 FUSING UNIT REMOVAL
1. Open the right front door, turn the fusing unit release lever [A]
counterclockwise, and pull out the fusing & inverter unit [B].
2. Turn the fusing unit release lever clockwise and remove it (1 screw).
Remove the fusing cover [C] (3 screws).
3. Disconnect the following connectors:
Fusing lamp [D] (front and rear: 1 connector each)
Thermofuse [E]
Thermistor [F]
4. Open the inverter unit [G] and remove the fusing unit [H] (2 screws).
[D]
[G]
[B]
[C]
[A]
[D]
[F]
[E]
[H]