9
SP Adjustment – 2 (PAGE 4)
Item
Function
Range
Change/
Step
+
Transfer/Separation
Corona ON Timing
Adj.
Changes the ON timing of normal
separation corona after leading edge
separation.
±
16
Approx.
2 mm
Delay ON
timing
ADS Sensor
Adjustment
Changes the range of the ADS
voltage for ADS compensation.
±
7
30 V
Lighter
Exposure Lamp Adj. Adjusts the light intensity of the
exposure lamp.
±
16
1.3%
Increase
light
intensity
Fusing Temperature
Adj.
Adjusts the hot roller temperature.
Use this mode with a thermometer.
±
16
Approx.
1°C
Lower
temperature
Latent Image
(Vd, Vb,Vl) Adj.
Reduce Vd, Vb, and V
L1
to prevent
the charge corona from arching
abnormally (causing black spots on
copies) in high altitude areas.
0 ~ 9
20 V
(Vd)
15 V
(V
B
, V
L1
)
Lower
voltages
ADS Sensor Adjustment
NOTE: For factory use, V
BA
+ V
BADJ
can be reduced below 0 V using the
ADS sensor adjustment for testing in SP mode. Check the copy
quality in ADS mode after exiting the SP mode. For routine
operation, V
BA
+ V
BADJ
is limited to 0 V or more. In the field, adjust
the ID selection in ADS mode (V
BS
, SP Special Features:
Index 4-6).
A171M527.img
10
SERVICE PROGRAM MODE
1 July 1995
4-20
Summary of Contents for FT8680
Page 3: ...SECTION 1 OVERALL MACHINE INFORMATION ...
Page 8: ...MEMO 31 July 1995 SPECIFICATIONS 1 5 ...
Page 23: ...6 5 IMAGE OVERLAY MODE 2ND SIDE A171V505 wmf PAPER PATH 31 July 1995 1 20 ...
Page 24: ...SECTION 2 DETAILED SECTION DESCRIPTIONS ...
Page 133: ...Timing Chart 1 Stack 2 Paper Feed A171D551 wmf A171D552 wmf 31 July 1995 DUPLEX 2 109 ...
Page 159: ...SECTION 3 INSTALLATION ...
Page 177: ...SECTION 4 SERVICE TABLES ...
Page 229: ...SECTION 5 REPLACEMENT AND ADJUSTMENT ...
Page 362: ...SECTION 6 TROUBLESHOOTING ...