9
SP Adjustment – 1 (PAGE 1, 2, and 3)
1. Function
Turn on the individual power pack. Two or more power packs cannot be
turned on at the same time in this mode.
2. Test Procedure
Touch
to turn on and touch to turn off.
NOTE: This mode may damage the drum; so, do this only with an old drum.
3. Code Table
Use to adjust an output voltages
from the power packs. Output values
change by 0.5% per step.
NOTE: This adjustment should only
be carried out when the
RAM clear has to be done.
Do not use this mode in the
field except for the RAM clear
procedure.
RESET
SET
A171M524.img
A171M525.img
A171M526.img
C
Charge corona
T1
Transfer corona - first side
T2
Transfer corona - second side
T3
Transfer corona - leading edge
T4
Transfer corona - leading edge
(translucent paper.)
PTC
Pre-transfer corona
D1
Separation corona - first side
D2
Separation corona - second side
D3
Separation corona - leading edge
D4
Separation corona - leading edge
(translucent paper.)