1.3.10 ADS Adjustment
The ADS pattern is located underneath the exposure glass bracket. During
the process control data initialization, the ADS reference voltage is adjusted.
When the first scanner is moved to the return position for the Vd adjustment,
the main PCB checks the ADS voltage through the ADS fiber optics cable.
The measured voltage is calibrated to the standard voltage (3 V) as the
reference for the auto image density control.
ADS Pattern
A171D508.wmf
ADS Pattern
Exposure Glass
A171D570.img
31 July 1995
PROCESS CONTROL
2-13