6.4.2 Bias Control In Copy Cycle
The bias output is determined by four factors.
The total bias is described as;
V
B
= V
BB
+ V
BA
+ V
BADJ
+ V
BS
(ADS Mode)
V
B
= V
BB
+ V
BM
(Manual ID Mode)
1) Base Bias (V
BB
)
As explained in the process control section, the base bias for development is
determined by the drum light potential (V
L
) measured in each original scan.
The base bias is also affected by the exposure lamp adjustment setting in the
SP mode.
V
BB
= V
L2
+ 280 –
∆
V + 10 N – 15 M
∆
V = V
L2
– V
r
(Maximum
∆
V = 210, Minimum
∆
V = 110)
NOTE: N = Number of the lamp adjustment setting in SP mode.
M = Number of the Latent Image Adj. in SP mode.
Drum
Potential
Dark
Light
Original Density
V
BB
V
0
Vd
V
L
Vr
A171D528.wmf
DEVELOPMENT
31 July 1995