5.10 EXPOSURE LAMP CONTROL
Exposure lamp intensity must be stabilized during the copy cycle to get a
constant latent image on the drum. The main PCB [A] monitors and maintains
the light intensity through a fiber optics cable [B]. According to the measured
value, a lamp power signal (PWM signal) is sent to the fluorescent lamp
stabilizer [C].
The PWM signal output is determined based on the standard value (+3 V at
PWM 100% duty cycle) which is set at the process control data initialization
(see the Process Control Section for details).
[C]
[B]
[A]
PWM
A171D572.img
OPTICS
31 July 1995
2-34
Summary of Contents for FT8680
Page 3: ...SECTION 1 OVERALL MACHINE INFORMATION ...
Page 8: ...MEMO 31 July 1995 SPECIFICATIONS 1 5 ...
Page 23: ...6 5 IMAGE OVERLAY MODE 2ND SIDE A171V505 wmf PAPER PATH 31 July 1995 1 20 ...
Page 24: ...SECTION 2 DETAILED SECTION DESCRIPTIONS ...
Page 133: ...Timing Chart 1 Stack 2 Paper Feed A171D551 wmf A171D552 wmf 31 July 1995 DUPLEX 2 109 ...
Page 159: ...SECTION 3 INSTALLATION ...
Page 177: ...SECTION 4 SERVICE TABLES ...
Page 229: ...SECTION 5 REPLACEMENT AND ADJUSTMENT ...
Page 362: ...SECTION 6 TROUBLESHOOTING ...