1. INSTALLATION REQUIREMENT
1.1 ENVIRONMENT
1. Temperature Range:
10°C to 30°C (50°F to 86°F)
2. Humidity Range:
15% to 90% RH
3. Ambient Illumination:
Less than 1,500 lux (do not exposure to direct
sunlight)
4. Ventilation:
Minimum space 20 m
3
.
Room air should turn over
at least 30 m
3
/hr/person.
5. Ambient Dust:
Less than 0.15 mg/m
3
(4 x 10
-6
oz/yd
3
)
6. If the machine location is air-conditioned or heated, place the machine:
a) where it will not be subjected to sudden temperature changes.
b) where it will not be directly exposed to cool air from an air-conditioner
in the summer.
c) where it will not be directly exposed to reflected heat from a space
heater in winter.
7. Avoid placing the machine in an area filled with corrosive gas.
8. Avoid any places higher than 2,000 meters (6,500 feet) above seal level.
9. Place the machine on a strong and level base.
10. Avoid any area where the machine may be frequently subjected to strong
vibration.
1.2 MACHINE LEVEL
1. Front to back level:
within 5 mm (0.2")
2. Right to left level:
within 5 mm (0.2")
31 July 1995
INSTALLATION REQUIREMENT
3-1
Summary of Contents for FT8680
Page 3: ...SECTION 1 OVERALL MACHINE INFORMATION ...
Page 8: ...MEMO 31 July 1995 SPECIFICATIONS 1 5 ...
Page 23: ...6 5 IMAGE OVERLAY MODE 2ND SIDE A171V505 wmf PAPER PATH 31 July 1995 1 20 ...
Page 24: ...SECTION 2 DETAILED SECTION DESCRIPTIONS ...
Page 133: ...Timing Chart 1 Stack 2 Paper Feed A171D551 wmf A171D552 wmf 31 July 1995 DUPLEX 2 109 ...
Page 159: ...SECTION 3 INSTALLATION ...
Page 177: ...SECTION 4 SERVICE TABLES ...
Page 229: ...SECTION 5 REPLACEMENT AND ADJUSTMENT ...
Page 362: ...SECTION 6 TROUBLESHOOTING ...