6.1 CALL SERVICE CONDITIONS
Unit
Code
Definition
Detail
Exposure
11
Exposure lamp malfunction
Displayed if the lamp filament is broken or if the lamp turns on during stand-by.
12
Lamp relay malfunction
Displayed if the lamp stays off or the lamp stays on longer than 10
±
4 seconds
during a copy cycle.
Optics
21
Scanner home position not on
At power-up, the scanner home position sensor output is checked during the
scanner position initialization. (At home position, there should be less than 4.5 V
at CN403-4 on the main board.)
22
Scanner home position not off
23
No registration start signal
Displayed when the main board does not receive the registration start signal
from the optics CPU 4.9 seconds after the 1st scanner has started to move.
24
No home position signal
Displayed if the main board does not receive the H.P signal from the optics
CPU 20 seconds after the scanner return signal is initiated.
25
Scanner motor failure
Displayed if the scanner drive rotation direction is not detected.
28
Lens home position not on
Displayed if the lens is moving towards enlargement and the H.P sensor stays
at a low signal level for longer than 3.7 seconds.
29
Lens home position not off
Displayed if the lens H.P. sensor stays at a high signal level longer than 3
seconds when the lens is moving towards reduction.
2A
2nd scanner home position not on
Checked when lens has started to move.
2B
2nd scanner home position not off
2C
High frequency encoder output
The output of the scanner motor encoder is checked when the scanner is
moving.
2D
Low frequency encoder output
2E
No encoder pulse
Displayed when no encoder pulse is detected.
Drum
31
Drum thermistor blown
Displayed when the drum thermistor circuit is open.
Fusing
52
Thermofuse blown
Displayed if the thermofuse or the fusing thermistor is open.
53
Thermistor blown
54
Ready signal not on
Displayed if the ready signal is not received within 8 minutes after the power
relay turns on.
55
Fusing unit overheat
Displayed if the resistance of the thermistor becomes too low.
Drive
61
Pulse generator malfunction
Displayed if the CPU does not receive a pulse for longer than 1 second during a
copy cycle.
- 99 -
Summary of Contents for FT5034
Page 1: ...SERVICE MANUAL FT5034C...
Page 3: ...1 INSTALLATION 1 1 INSTALLATION REQUIREMENTS 3 1 2 INSTALLATION PROCEDURE 4 2...
Page 8: ...2 OVERVIEW 2 1 SPECIFICATIONS 8 2 2 GUIDE TO COMPONENTS 9 7...
Page 10: ...2 2 GUIDE TO COMPONENTS 1 Operation Panel 9...
Page 11: ...2 Indicator Panel 10...
Page 12: ...3 COPY PROCESS 3 1 COPY PROCESS DIAGRAM 12 11...
Page 115: ...8 TROUBLESHOOTING 114...