background image

11. ADS Voltage Adjustment

NOTE: 1. ADS voltage adjustment is required in the following cases.

1) Exposure lamp voltage adjustment.
2) Exposure lamp replacement.
3) When using ADS mode, abnormal copy image appears.
4) Main board replacement.

  1. Place more then 5 sheets of A3 paper on the exposure glass.

  2. Turn on DIP SW101-1 on the main board (free run mode).

  3. Set SP mode (88) to "11". (Refer to the SP mode access procedure.)

  4. Leave SP mode.

  5. Access ADS input mode as shown.

Interrupt key 

 "4" key 

 Interrupt key

  6. Press the Start key.

  7. Adjust the ADS voltage to 3.0 

±

 0.06 V as displayed in the magnification indicator

of the operation panel by using VR102 on the main board.

NOTE: 1. Remove the 1st cassette from the copier to make full scans so that

the adjustment will be easy.

2. Adjusting VR102 should be done based on the data after 3 scans.

3. The ADS data is based on the data when the exposure lamp moves

from the home position to the center of exposure glass.

4. After the adjustment, be sure that the SP mode and DIP SW are

reset. (Set SP mode (88) to "10".)

5. When adjusting ADS voltage, set the image density mode to

"automatic image density mode".

- 43 -

Summary of Contents for FT5034

Page 1: ...SERVICE MANUAL FT5034C...

Page 2: ...ENTS 1 INSTALLATION 2 2 OVERVIEW 7 3 COPY PROCESS 11 4 SECTION DESCRIPTIONS 13 5 SP MODE DIP SW TABLE 92 6 CALL SERVICE CONDITIONS 98 7 PREVENTIVE MAINTENANCE 105 8 TROUBLESHOOTING 114 9 ELECTRICAL DA...

Page 3: ...1 INSTALLATION 1 1 INSTALLATION REQUIREMENTS 3 1 2 INSTALLATION PROCEDURE 4 2...

Page 4: ...rea filled with dust and subjected to frequent strong vibration Avoid narrow space 10 m3 2 Access to Copier Place the copier near a power source providing clearance as shown The copier must be level w...

Page 5: ...e copier as follows 1 From platen cover to front cover 2 Manual table 3 Feed guide cassette insert section 4 Transport guide plate 5 T S corona unit 6 Toner shield glass 7 Front loading cassette lever...

Page 6: ...lever 2 Remove the charge corona unit together with the wire cleaner 1 screw 3 Remove the drum stay 1 knob and 1 screw The drum knob is reverse threaded 4 Pull out the drum protective sheet 5 Reinsta...

Page 7: ...from red to green after 2 min 2 Lower the platen cover and enter 99 using the number keys and press the Start key Drum conditioning takes about 5 min 3 After the drum conditioning is finished open the...

Page 8: ...2 OVERVIEW 2 1 SPECIFICATIONS 8 2 2 GUIDE TO COMPONENTS 9 7...

Page 9: ...Enlargement Less than 3 5 seconds Enlargement Reduction Less than 5 0 seconds Photoconductor Selenium drum F type Development System Magnetic brush system Image Density Control Development Bias system...

Page 10: ...2 2 GUIDE TO COMPONENTS 1 Operation Panel 9...

Page 11: ...2 Indicator Panel 10...

Page 12: ...3 COPY PROCESS 3 1 COPY PROCESS DIAGRAM 12 11...

Page 13: ...ed on and at every 10th copy after that 6 PRE TRANSFER LAMP PTL The PTL illuminates the drum to remove all positive charge from the exposed areas of the drum This prevents the toner particles from bei...

Page 14: ...CAL COMPONENT LAYOUT 16 4 4 PAPER FEED AND REGISTRATION 18 4 5 OPTICS 28 4 6 AROUND THE DRUM 44 4 7 DEVELOPMENT AND TONER SUPPLY 50 4 8 ID SENSOR AND PTL 62 4 9 IMAGE TRANSFER PAPER SEPARATION AND PAP...

Page 15: ...Separation Corona Wire 14 Drum 15 Charge Corona Wire 16 Transfer Corona Wire 17 Erase Lamp 18 Development Unit 19 4th Mirror 20 Feed Roller By pass Feed 21 Toner Tank 22 Pick up Roller 23 Pressure Le...

Page 16: ...F Belt Drive Motor Gear 11 DF Feed Roller 12 Bin Transfer Wheel 13 Bin Support Rack 14 Bin Support Pinion Gear 15 Bin Drive Motor Gear 16 Sorter Adapter Feed Motor Pulley 17 Sorter Adapter Drive Belt...

Page 17: ...12 Door Switch 13 2nd Feed Clutch 14 Relay Roller Clutch 15 F L Front Loading Feed Clutch 16 F L Tray Paper End Sensor 17 Cleaning Solenoid 18 Main Power Relay 19 Main Switch 20 Power Supply Board 21...

Page 18: ...Vacuum Fan 45 Erase Lamp 46 ID Sensor Board 47 PTL Pre Transfer Lamp 48 Registration Sensor Board 49 2nd Cassette Paper Size Sensor 50 1st Cassette Paper Size Sensor 51 By pass Table Sensor 52 By pass...

Page 19: ...clutch the paper feed clutches are all magnetic clutches The CPU turns on the paper feed clutch for the required station at a programmed time after the Start key is pressed Upon receiving the signal...

Page 20: ...ce The paper size sensors are actuated by a plate on the front of the cassette Each paper size has its own unique combination of notches in the actuator plate For the front loading feed station if pap...

Page 21: ...e guides allow the release levers to move back up The cassette arm then presses up the cassette bottom plate until the paper contacts the paper feed roller 5 Registration The registration rollers have...

Page 22: ...pad system To use a larger size than B4 at the by pass feed table the large cassette must be installed in order to support the trailing part of the paper When the by pass feed table is opened the pic...

Page 23: ...r a photointerrupter is activated and the copier enters by pass feed mode The by pass feed mode is the same as interrupt mode When the by pass feed table is opened the copier stores the previous job s...

Page 24: ...I 102 24A Size 4 I 102 22B Size 5 I 102 25A Paper End 1 I 102 23B Paper end detection Paper End 2 I 102 25B 1st Feed MC O 101 5A 2nd Feed MC O 101 3A By pass Feed MC O 101 10A F L Feed MC O 101 2A Rel...

Page 25: ...e hub is positioned toward the rear on the shaft 4 Remove the friction pad holder by pressing the lower hooks using long nose pliers 5 Peel off the friction pad and stick a new pad on the friction pad...

Page 26: ...with Mobil Temp 78 7 Reinstall the friction pad holder NOTE Be sure the legs of the friction pad holder are positioned under the spring loaded pad positioning mechanism The eccentric cam should be sec...

Page 27: ...vel surface of the friction pad holder with Mobil Temp 78 9 Reinstall the friction pad holder on the holder bracket NOTE The eccentric cam should be secured in the original position referring to the m...

Page 28: ...the following adjustment 1 Remove the cassette 2 Turn the eccentric cam A to adjust the friction pad pressure as shown in figures 1 and 2 NOTE If the eccentric cam groove is aligned vertically the gap...

Page 29: ...tion ratios six reductions three enlargements and full size In addition it has a zoom function The user can change the reproduction ratio in one percent steps from 50 to 200 This machine has an automa...

Page 30: ...racket As the lens motor is a stepper motor the rotation of the lens drive pulley moves the lens back and forth in discrete steps The lens home position sensor informs the optics CPU IC403 when the le...

Page 31: ...closer together The plates block part of the light passing through the lens to keep the intensity of the light on the drum even 3 2nd Scanner Drive In order to provide the proper optical distance betw...

Page 32: ...ricted at reproduction ratios of 156 200 This causes partial enlargement because the lens restricts exposure lamp movement ex Effective original area at 200 enlargement Copying can be in the range as...

Page 33: ...maximum sample voltage and changes the development bias accordingly The exposure lamp voltage is constant equal to the voltage at the manual density level 4 regardless of the image density of the orig...

Page 34: ...F OFF Nor mal OFF small OFF OFF OFF small OFF OFF Nor mal OFF OFF ON OFF ON ON OFF ON OFF ON ON ON ON TB 0 2 Pitch E 0 8 mm Pitch TB Vertical magnification Scanner speed E Lead edge erase R Lead edge...

Page 35: ...f before replacement 1 Remove the exposure glass 2 Move the first scanner to the position where the rear frame is cut out 3 Remove the reflector cover 2 screws 4 Wrap a strip of paper around the expos...

Page 36: ...1 Do not adjust vertically using the adjusting knob 2 If the adjustment is incorrect uneven image density or dirty background will appear on the copy image 4 2nd and 3rd Mirror Replacement 1 Remove th...

Page 37: ...Replacement 1 Remove the top cover 12 screws 2 Remove the sub reflector 2 screws 3 Remove the upper seal at the front side 4 Free the lamp harness from the bracket 1 screw 5 Lift the 1st scanner thro...

Page 38: ...nstall the mirror with the reflecting surface uppermost 2 Install the mirror with the cutout part facing down 3 Attach the spring plate to the non reflecting surface 11 Position the front spring plate...

Page 39: ...ve the rear cover 3 screws and lower the PCB plate 2 screws 5 Remove the damper wheel 6 Loosen the wire clamp screw 7 Remove the lamp stabilizer bracket 1 screw 8 Move the 2nd scanner to the return po...

Page 40: ...5 Lower side Wire Clamp 6 Lower track WP3 7 Inner track WP4 8 Three and half turns from lower to upper Scanner Drive Pulley 9 Outer track WP4 10 Lower track WP5 11 Inner track WP2 12 Outer track WP6...

Page 41: ...scale 2 short screws and the exposure glass 4 Remove the rear cover 3 screws and lower the main board bracket 2 screws 5 Tape the scanner drive pulley and the wire pulleys A 6 Loosen the scanner driv...

Page 42: ...ve wire in the left fork and wrap the wire around the lens drive pulley for three and half turns 2 Run the wire on the tension pulley and set the wire bead in the right fork 3 Set the tension spring 8...

Page 43: ...be faintly visible on the copy when the 4th level of the density control is selected 1 Clean the optics mirrors lens reflectors exposure glass toner shield glass 2 Turn on the main switch and allow it...

Page 44: ...rrupt key 4 key Interrupt key 6 Press the Start key 7 Adjust the ADS voltage to 3 0 0 06 V as displayed in the magnification indicator of the operation panel by using VR102 on the main board NOTE 1 Re...

Page 45: ...en the C B power pack applies a high positive voltage 5 0 kV 7 5 kV The selenium coating receives a uniform positive charge 700 50 V as it rotates past the corona unit The main motor fan provides a sm...

Page 46: ...drum TH 1 determines the proper rest time compensation and TH 2 controls the development bias voltage A Lead Edge Erase Margin 3 5 0 5 mm B Side Margins 2 2 mm each For full size copies the total of b...

Page 47: ...once every ten cycles the center block of erase lamps turns off long enough for the sensor pattern to be developed 2 Side Erase Based on the paper size and on the reproduction ratio the LEDs turn on i...

Page 48: ...n Ratio Data 0 off 1 on Ratio 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 50 53 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0 54 57 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0 0 58 60 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0 0 0 61 63 1...

Page 49: ...r the light intensity of the QL is slightly less than that of the PTL This is because of the darkness of the filter colors The cold cathode lamp has the characteristics of low power consumption and lo...

Page 50: ...py image will be erased lead edge erase T4 1 23 seconds after the Start key is pressed mode erase begins T5 If full erase begins after 2 49 seconds of erase the charge turns off T6 The T S charge PCC...

Page 51: ...ddles and transports it to the development roller Internal permanent magnets in the development roller attract the developer to the development roller sleeve The turning sleeve of the development roll...

Page 52: ...is moved slightly toward the rear of the unit by the mixing vanes Part of the developer falls into the auger inlet and is transported to the front of the unit by the mixing auger 3 Drive Mechanism The...

Page 53: ...to the background from being developed this prevents dirty background The development bias voltage is supplied from the power pack C B to the bias terminal via the bias terminal plate 1 Bias Control...

Page 54: ...r increases the bias at the begining of each copy run to prevent variations in the image density of the first few copies produced The amount of bias increase is shown in the two tables below If the dr...

Page 55: ...copy counter to 11 or more After turning the ready indicator on press the Start key and measure the bias voltage NOTE Read the bias after the 11th copy in order to get the value without any rest time...

Page 56: ...toner supplied and can be changed by using SP mode 30 1 Detect Supply Mode P mode The main CPU checks toner density by directly detecting the image density If toner density is too low the toner supply...

Page 57: ...than five seconds If Vsp becomes greater than 0 8 volt twice the CPU starts blinking the Add Toner indicator After the indicator starts blinking the operator can make up to 50 copies then copying is...

Page 58: ...its output the bias for the copy image is applied T2 If the toner density is too low the toner supply clutch turns on 0 55 second after the scanner motor reverses The time is 0 98 second at the 30 su...

Page 59: ...1 0 0 290 2 5 0 1 0 1 320 1 7 2 16 2 6 6 0 1 1 0 350 7 0 1 1 1 380 1 65 2 16 8 1 0 0 0 410 9 1 0 0 1 440 1 65 10 1 0 1 0 500 11 1 0 1 1 500 12 1 1 0 0 530 13 1 1 0 1 560 14 1 1 1 0 590 15 1 1 1 1 620...

Page 60: ...ased by 90 volts 4 7 3 Replacement and Adjustment NOTE When removing or reinstalling the development unit apply force towards the right side to avoid scratching the drum 1 Developer Replacement 1 Open...

Page 61: ...angle and dump out the developer that has collected at the ends of the development unit 7 Repeat the above steps until you have removed all of the developer NOTE If developer remains in the developme...

Page 62: ...support bracket 3 screws 1 E ring and 1 nylon clamp 5 Remove the pulse generator disk 6 Remove the toner supply clutch from the drive shaft 7 Install a new toner supply clutch 8 Reassemble the copier...

Page 63: ...r pattern is erased by an erase lamp After the latent image is developed but before the image is transferred to the copy paper the drum surface is illuminated by the pre transfer lamp This illuminatio...

Page 64: ...er block of the erase lamps turns off A5 Lengthwise size long enough for the sensor pattern to be developed When the sensor pattern image on the drum is over the ID sensor the LED of the ID sensor tur...

Page 65: ...nsity of the developer because it indicates the reflected light intensity from the sensor pattern The pattern is developed by using the present developer in the machine The toner density will be contr...

Page 66: ...V When the toner is supplied the toner density becomes higher and the ID sensor pattern image becomes darker Consequently Vsp is lower than the reference value and the toner is not supplied 4 Abnormal...

Page 67: ...gh strong 2 Exposure weak rapid 3 Drum Sensitivity slow high 4 Development Bias low light dark high low supplied no supplied high low return to the original condition Variation Factor Image Density Vs...

Page 68: ...IGH OFF ON 30 ON OFF 45 OFF ON HIGHER ON ON 60 ON ON Set up procedure P Mode a Set SP mode 30 to 10 b Leave SP mode c DPS101 3 ON DPS101 4 OFF P mode 30 3 The toner density can be changed by the chang...

Page 69: ...rmal full erase for the lead edge erase 0 18 second later T3 When checking the toner density the ID sensor LED turns on 1 20 seconds after the Start key is pressed and ID sensor output is sent to the...

Page 70: ...ve the rear cover 3 screws 2 Lower the main board bracket 2 screws 3 Remove the registration clutch stopper 1 screw 4 Remove the ID sensor connector 1 screw 5 Slide out the pre transfer lamp 1 screw a...

Page 71: ...the main board 5 Place five sheets of A3 paper on top of each other on the exposure glass and lower the platen cover 6 Hook up the positive lead of a multimeter to TP103 ID sensor output check on the...

Page 72: ...ation corona wires apply an ac corona to the reverse side of the paper The stiffness and the weight of the paper then cause it to separate from the drum 4 9 2 Mechanical Parts 1 Overview The registrat...

Page 73: ...pin on the cam drive gear rotates the cam wheel This wheel has six slots in which the pin catches so the cam wheel turns 1 6 of a revolution for each full turn of the cam drive gear The cam part of th...

Page 74: ...r cover and lower the main board bracket 2 screws 7 Disconnect all the connectors of the T S PCC power pack and remove the power pack 1 screw 8 Remove the cam lever assembly 1 screw 9 Disconnect the v...

Page 75: ...13 Remove the front of the transport unit as shown 1 E ring 1 spring and 1 shaft 14 Pull the right transport wheel and belt to the right and remove the transport wheel 15 Remove the transport belt 74...

Page 76: ...de the cleaning unit As the brush turns inside the cleaning unit it rubs against a beater ridge which dislodges the toner particles The toner particles fall onto the toner collection coil The toner co...

Page 77: ...the positively charged toner and removes about half of it from the drum This further reduces the load on the cleaning blade 3 Drive Mechanism The main chain drives the cleaning unit when the main mot...

Page 78: ...g at each end to apply even pressure if it is mounted in this way The blade scraper is mounted in contact with the bottom side of the cleaning blade When pressure is applied to the cleaning blade it i...

Page 79: ...ontact the drum in the same place but instead move slightly to the side on each copy cycle The pick off shaft and the cam rider are joined by a one way bearing Each time the pick off pawl solenoid tur...

Page 80: ...it turns off 0 12 second after the fusing exit sensor turns off T3 The pick off pawl solenoid starts 1 49 seconds after the Start key is pressed and the pick off pawls contact the drum After 1 0 secon...

Page 81: ...ck off pawls are kept away from the drum when removing the cleaning unit or serious drum damage will result 2 Cleaning Blade Replacement 1 Take out the cleaning unit See Cleaning Unit Removal 2 Remove...

Page 82: ...ection coil cover 1 screw 3 Slide out the toner collection coil from the front of the cleaning unit NOTE Toner will fall out when the coil is pulled 4 Remove the pawl shaft pin from the pawl shaft 5 P...

Page 83: ...e figure 2 Make sure that the spring end is in the small hole on the rear side plate 12 Install the pawl shaft pin 13 Push the spring collar to the rear and rotate it one turn as shown in the figure T...

Page 84: ...ff to maintain the operating temperature Pressure roller The pressure roller presses the paper into contact with the hot roller The pressure comes from two pressure springs Thermistor The CPU monitors...

Page 85: ...ween the two fusing rollers The release gear spring allows the release gear to move in and out This prevents the gears from being damaged if they should not engage correctly when the fusing unit is in...

Page 86: ...nt any variation in the scanner motor speed or the exposure lamp intensity When the scanner starts moving in reverse fusing lamp control again shifts to ON OFF control 3 Service Call Conditions 1 Stat...

Page 87: ...th your hands because finger oil marks may damage the lamp 3 Swing down the fusing exit assembly and unhook the pressure springs 4 Remove the harness support bracket 2 screws and 2 hooks 5 Remove the...

Page 88: ...Remove the fusing unit and cover 2 screws 2 Swing down the fusing exit assembly and unhook the pressure springs 3 Remove the fusing knob and the oil pan 1 screw each 4 Remove the front pressure lever...

Page 89: ...screw 3 Remove the thermofuse wire from the metal wire clamp 1 screw 4 Disconnect the thermofuse 1 connector and install the new thermofuse 6 Thermistor Replacement 1 Remove the fusing unit and the fu...

Page 90: ...ocation A Feeding Section Location B Fusing Unit Location D Sorter Location E ADF After removing the misfed paper make sure that all units and levers are returned to their original positions and the f...

Page 91: ...ice Call Conditions Self Diagnostic Code 61 1 Definition This code is generated if the CPU does not receive a pulse for longer than 1 second during a copy cycle 2 Symptoms When the Start key is presse...

Page 92: ...s 2 Remove the 2 screws securing the operation panel to the inner panel brackets 3 Slide the operation panel toward the front and lift it off the side panel brackets 4 Disconnect the dc harness from t...

Page 93: ...5 SP MODE DIP SW TABLES 5 1 SERVICE PROGRAM MODE 93 5 2 DIP SWITCH TABLES 96 5 3 INPUT CHECK MODE 97 92...

Page 94: ...MODE NUMBER USING THE NUMBER KEYS THE SP MODE NUMBER AND 1 WILL BLINK ALTERNATELY IN THE COPY COUNTER RECALL ENTER Change the setting PRESS THE 0 OF THE NUMBER KEYS WHEN YOU WISH TO CHANGE THE SETTIN...

Page 95: ...Toner Supply Mode 10 10 P MODE Detect Supply Mode 11 C MODE Fixed Supply Mode 33 ID Sensor Bias Color NOTE 6 10 10 Normal 590 volts 11 High 620 volts 34 Image Bias Up 10 10 Normal 11 The Development B...

Page 96: ...ormed This procedure is required only when the copier malfunctions due to a damaged RAM board or when the RAM board is replaced CAUTION Memory all clear is done immediately after you press the 0 key t...

Page 97: ...ON ON LARGE ON ON FOR PRODUCTION NORMALLY ON ON OFF ON OFF OFF ON OFF ON OFF OFF OFF OFF OFF NORMAL SMALL OFF OFF SMALL OFF OFF OFF ON OFF ON ON OFF ON OFF ON ON ON ON TB 0 2 Pitch E 0 8 mm Pitch 3 D...

Page 98: ...ith this input check mode you have to leave the SP mode MODE 1 2 3 4 REMARKS Vsp 1 Vsg 1 While the key is hold down BIAS Voltage 1 While the 0 key is held down ID SENSOR Input Voltage 2 ADS Data 3 ADS...

Page 99: ...6 CALL SERVICE CONDITIONS 6 1 CALL SERVICE CONDITION CODES 91 6 2 CALL SERVICE CONDITION DETAILS 92 98...

Page 100: ...ion is not detected 28 Lens home position not on Displayed if the lens is moving towards enlargement and the H P sensor stays at a low signal level for longer than 3 7 seconds 29 Lens home position no...

Page 101: ...ERVICE CONDITION DETAILS PROBLEM CAUSE ACTION STATUS 11 LAMP MALFUNCTION 1 LAMP REGULATOR MALFUNCTION 2 EXPOSURE LAMP OPEN 3 MAIN BOARD MALFUNCTION 1 Check if the exposure lamp is lit during stand by...

Page 102: ...NER MOTOR MALFUNCTION 1 Replace the main board 2 Check the scanner motor and replace it if necessary STATUS 24 NO HOME POSITION SIGNAL 1 MAIN BOARD MALFUNCTION OPTICS CONTROL SECTION 1 Replace the mai...

Page 103: ...output of the scanner motor If it is malfunctioning replace the scanner motor 2 Replace the main board 3 Check the voltage of the power source wall outlet STATUS 31 DRUM THERMISTOR BLOWN 1 DRUM THERMI...

Page 104: ...POWER RELAY 12 15 220V FUSING UNIT CONNECTOR IS FUSING CONTROL BOARD CN1 8 LOW REPLACE THE POWER RELAY CHECK THE FUSING LAMP IS BLOWN CHECK THE FUSING UNIT CONNECTOR REPLACE THE OPERATION PANEL REPLAC...

Page 105: ...d 4 If the voltage at 1 2 of CN2 on the main motor is not 220V replace the SSR of the PSU and if it is 220V replace the main motor STATUS 91 TOTAL COUNTER MALFUNCTION 1 TOTAL COUNTER MALFUNCTION 2 MAI...

Page 106: ...7 PREVENTIVE MAINTENANCE 7 1 OVERVIEW 98 7 2 PM TABLE 99 7 3 EXPLANATION OF REGULAR PM 101 7 4 REGULAR PM PROCEDURE 103 105...

Page 107: ...exchange of worn out parts 2 Removal of dirt to maintain good copy quality 3 Inspection and adjustment to maintain good copy quality 4 Lubrication 5 Replacement of defective parts 6 At service call d...

Page 108: ...ace the friction pad and entrance seal mylar as a set for the front loading cassette 11 Registration rollers O O O Alcohol or water 12 Paper feed guide plate O O O Alcohol or water 13 Registration sen...

Page 109: ...42 Exit brush O O O Drive unit 43 Drum drive belt Replace if necessary 44 Drive chain Mobil temp 78 45 Bushings Spindle oil Others 46 Exposure lamp voltage Check using input check mode at manual imag...

Page 110: ...opy may become dirty Cleaning is required at regular intervals Around Drum Corona Wires Dirty corona wires may cause uneven image density They should be cleaned or replaced at regular intervals End Bl...

Page 111: ...wls at regular intervals Fusing Entrance and Exit Guides Toner piling up on the guide plate will cause a dirty background on the copy Clean the guide plate at regular intervals ADF Transport Belt A di...

Page 112: ...um in clean sheets of paper to protect it Around the drum every 40K 1 Clean the end blocks casing and transfer guide plate with a damp cloth and wipe them with a dry cloth 2 Clean the QL and PTL filte...

Page 113: ...ers and friction pads Machine rear side every 40K 1 Clean the ID sensor and registration sensor with a blower brush 2 Inspect the drum drive belt Machine rear side every 80K 1 Lubricate the main drive...

Page 114: ...Lubricate the oilless bushings using spindle oil Exterior unit Clean the covers Copy quality After performing drum conditioning for 10 copies turn off the DIP SW on the operation panel board and make...

Page 115: ...8 TROUBLESHOOTING 114...

Page 116: ...ly visible image will appear on the copy image However when the bias charge P P fails no image will appear 3 The development roller does not turn Due to slippage of the roller or a broken drive gear c...

Page 117: ...Bias Voltage 1 Check the Development Roller 2 Check the Development Roller Gear 1 Check the charge corona wire 2 Check CN101 A17 on the main board goes from 5 to 0V 3 Check between conn 1 14 on the B...

Page 118: ...r toner scattered when the inlet seal is deformed 2 The mirror and exposure glass are contaminated by oil 3 Toner concentration is too high If toner concentration is too high toner will be scattered i...

Page 119: ...ck the lamp voltage It should be less than 160 V Lamp regulator output adjustment Dirty Background Charge Corona Toner Shield Glass Image Density too high Seal on the Dev Unit 2 1 Clean the toner shie...

Page 120: ...e adjust VDE VDE 3 0 0 06V 1 Doctor Gap is too wide Deterioration of Drum Deterioration of Developer VDE high 1 Adjust the lamp regulator Voltage 2 Replace the drum 1 Check the doctor gap 1 Replace th...

Page 121: ...ppears in non image areas The copied pattern changes depending on the reproduction ratio 1 Contamination of the mirrors and exposure glass Note If the image pattern does not change in any reproduction...

Page 122: ...harge Corona Mirrors and Exposure Glass Exposure Lamp 1 Clean the mirror lens and exposure glass 1 Check for exposure lamp deterioration 2 Adjust the exposure lamp positon 1 Clean the charge corona wi...

Page 123: ...ned with toner due to a defective inlet seal on the development unit 2 The lens and mirrors are dirty 3 The edge of the cleaning blade is damaged 4 An over concentration of toner causes the black stri...

Page 124: ...2 1 Check the toner shield glass 2 2 Clean the surface of the mirrors 2 3 Check the cleaning blade 2 4 Check the image density 3 1 Check for scratches on the drum 3 1 Check for scratches on the hot r...

Page 125: ...substance 1 Deformation of the PTL filter 2 Deformation of the ID sensor board 3 Deformation of the transfer separation guide plate An indistinct white line appears on the copy 1 The inlet seal on the...

Page 126: ...e charge corona wire sharp white lines will appear on the copy Vertical White Lines Charge Corona Cleaning Blade Foreign Substance Check the cleaning blade PTL ID Sensor Toner Pile up T S Guide Plate...

Page 127: ...e when the copier stops CASE 1 Cause If black lines appear at 151 mm from the leading edge of the paper Check 1 Check whether this black line appears at 151 mm intervals after making copies of other s...

Page 128: ...g Blade Check the seals on the dev unit Check the erase lamp Check the Drum Drum Check for scratches on the drum Clean the cleaning blade and cleaning brush If not solved replace both the cleaning bla...

Page 129: ...jitter appears on the copy It is especially noticeable in enlargement mode It may be caused by an incorrect voltage being supplied from the power supply unit 8 Scratch at 251 mm intervals Problem Caus...

Page 130: ...work replace the drum 2 If there is a horizontal black line clean the drum dust it with setting powder and then perform drum conditioning 99 copies Jitter Scanner Drive Motor Scanner Drive Pulley Pow...

Page 131: ...cur if the scanner lock plate is not mounted when transporting the copier Action Remarks 1 Check whether the scanners are parallel 2 Copy case 1 Raise the front side of the 1st scanner Copy case 2 Low...

Page 132: ...ing on the type of original used 2 The image density of black solid areas is too high 5 The toner supply ratio is greater than the actual usage If 45 supply in detect supply mode is selected and a sol...

Page 133: ...magnification counter Mark the toner supply shaft Press the Start key after the main switch is turned OFF and ON 2 6 revolutions per copy Check the toner supply clutch Is VSG 4 0 0 2 Adjust VR101 on...

Page 134: ...ensor To decrease toner density set DIP SW 101 3 OFF and 101 4 ON Make 10 20 copies in A3 size with the platen cover open Clean inside copier especially the PTL and ID sensor After turning the main sw...

Page 135: ...sity of solid areas is too low 2 The charge current is too high If the charge current is increased in order to improve solid black images Vsp is decreased lowering the image density 2 Solid black area...

Page 136: ...ification counter Mark on the toner supply Clutch Shaft Turn on DIP SW 101 2 on the main board Press the Start key 2 6 revolutions per copy Check the toner supply clutch Is VSG 4 0 0 2 Adjust VR101 on...

Page 137: ...in the size magnification counter going down No toner inside the toner cartidge Check the main control board Make 20 copies with the drum conditioning switch ON and check the revolution END 1 Yes No...

Page 138: ...1 The nip width is too narrow 2 The fusing temperature is too low 3 Thermistor malfunction Action Remarks 1 Replace the pressure spring on the fusing unit Deviation between front and rear must be les...

Page 139: ...urn position During copying the scanner is driven to the return position 1 Scanner motor malfunction 2 Optics control board malfunction Action Remarks 1 Measure the power source voltage when the main...