2. The toner supply control can be changed to C-Mode (fixed supply) or P-Mode
(detect supply) by SP mode (30).
The toner supply ratio is changed by the combined settings of DPS101-3, 4.
The default is 30% in P-mode.
DPS101
NO
1
2
MODE
3
4
Toner
Density
5
6
ON
FREE
RUN
SP
MODE
C MODE
3.5%
OFF
OFF
NORMAL
OFF
OFF
7%
ON
OFF
10.5%
OFF
ON
LOW
ON
OFF
14%
ON
ON
OFF NORMAL NORMAL
P MODE
15%
OFF
OFF
HIGH
OFF
ON
30%
ON
OFF
45%
OFF
ON
HIGHER
ON
ON
60%
ON
ON
Set up procedure (P-Mode)
a. Set SP mode (30) to "10".
b. Leave SP mode.
c. DPS101-3:
ON
DPS101-4: OFF
→
P-mode 30%.
3. The toner density can be changed by the changing the settings of DPS101-5 and
-6. The default is No 5: OFF, No 6: OFF, and the bias for the ID sensor pattern is
a constant 470 volts.
4. ID Sensor Monitor
a. Set SP mode (88) (Input Check) to "11".
b. Leave SP mode.
c. Select the ID sensor data monitor mode.
Interrupt key
→
1
→
Interrupt key = Vsp value
When the Enter/Recall key is pressed, Vsg is displayed.
d. Reset SP mode (88) (Input Check) to "10".
- 67 -
Summary of Contents for FT5034
Page 1: ...SERVICE MANUAL FT5034C...
Page 3: ...1 INSTALLATION 1 1 INSTALLATION REQUIREMENTS 3 1 2 INSTALLATION PROCEDURE 4 2...
Page 8: ...2 OVERVIEW 2 1 SPECIFICATIONS 8 2 2 GUIDE TO COMPONENTS 9 7...
Page 10: ...2 2 GUIDE TO COMPONENTS 1 Operation Panel 9...
Page 11: ...2 Indicator Panel 10...
Page 12: ...3 COPY PROCESS 3 1 COPY PROCESS DIAGRAM 12 11...
Page 115: ...8 TROUBLESHOOTING 114...