38
Counterpart Counting Scale Indicator
Feature Region Menu
TFORMT
T SEP
DFORMT
D SEP
TIME
NTEP
CANADA
INDUST
GROSS
BRUTTO
DOT
COMMA
NONE
OIML
COLON
COMMA
SLASH
DASH
SEMI
MMDDY4
DDMMY4
Y4MMDD
Y4DDMM
MMDDY2
DDMMY2
Y2MMDD
Y2DDMM
24 HOUR
12 HOUR
REGULAT
REGION
REGWORD
DECFMT
DATE
See
Figure 3-13. Region Menu Layout
Parameter Choices
Description
REGULA
NTEP
CANADA
INDUST
NONE
OIML
Regulatory mode. Specifies the regulatory agency having jurisdiction over the scale site.
Note
The value specified for REGULA affects the function of the front panel TARE and
ZERO keys.
•
OIML, NTEP, and CANADA modes allow a tare to be acquired at any weight greater than zero.
NONE allows tares to be acquired at any weight value.
•
OIML, NTEP, and CANADA modes allow a tare to be cleared only if the gross weight is at no
load. NONE allows tares to be cleared at any weight value.
•
NTEP and OIML modes allow a new tare to be acquired even if a tare is already present. In
CANADA mode, the previous tare must be cleared before a new tare can be acquired.
•
NONE, NTEP and CANADA modes allow the scale to be zeroed in either gross or net mode as
long as the current weight is within the specified ZRANGE. In OIML mode, the scale must be
in gross mode before it can be zeroed; pressing the ZERO key in net mode clears the tare.
•
INDUST provides a set of subparameters to allow customization of tare, clear, and print
functions in non-legal-for-trade scale installations.
When in legal-for-trade mode, refer to Section 9.10 on page 98 for more information on using this feature.
REGWOR
GROSS
BRUTTO
Sets the term printed when weighing in gross mode. Selecting BRUTTO replaces
Gross
with
Brutto
.
DECFMT
DOT
COMMA
Specifies whether decimal numbers are displayed using a period (DOT) or a comma.
TIME
TFORMT
T SEP
Allows you to set the current time, and the time format and separator character.
See Time sub-menu below.
DATE
DFORMT
D SEP
Allows you to set the current date, and date format and date separator character.
Time sub-menu
TFORMT
12 HOUR
24 HOUR
Sets the time format.
T SEP
COLON
COMMA
Sets the time separator as a colon or a comma.
Table 3-12. Region Menu Parameters