52
Counterpart Counting Scale Indicator
3.9
Display Menu
There are three display settings on the
Counterpart
.
0-100%
50
Negative
Positive
ID
DISPLAY
TEST
SETUP
AUDIT
CALIBR
SETPTS
CONTRAST
BRIGHT
IMAGE
100
0-100%
Figure 3-24. DISPLAY Menu
Setting the display parameters from this top level menu is temporary. After a power cycle, the values will revert to
their previous values. Changes made to these parameters through the CONFIG menu are kept through a power
cycle.
DIG I/O
LOOP
DIO 1
DIO 2
DIO 3
DIO 4
Tests your digital I/O ports. If they are functioning, PASS is displayed. If they are not functioning,
FAIL is displayed.
WARNING
Note
Both inputs and outputs are active low. They go to a ground state when active.
The I/O ports become activated when the test is performed. Make sure
any equipment is disconnected prior to performing this test to avoid
inadvertently activating it.
COMM
PORT1
PORT2
Performs a loop-back test on the serial ports. If they are functioning, PASS is displayed. If they are
not functioning, FAIL is displayed.
RAM
TEST
Tests the unit’s memory. If it is functioning, PASS is displayed. If it is not functioning, FAIL is
displayed.
KEYPAD
TEST
Tests the unit’s individual keypad buttons by displaying the name of the key pressed. If nothing is
displayed, the key is not functioning.
Press the Menu key to exit the test.
SCANNER
TEST
Displays scanned value with control characters.
A/D sub-menus
RAW
VAL
Displays the live current raw AD count.
ZERO
VAL
Displays the captured AD Zero calibration value.
SPAN
VAL
Displays the captured AD Span calibration value.
mV
VAL
Displays the live current millivolt signal voltage.
EXCVDC
VAL
Displays the current excitation voltage.
LOOP
TEST
Performs a loop test on dig I/O cards.
DIO 1
DIO 2
DIO 3
DIO 4
STATUS
Displays the status of each individual digital I/O port. If set as input, the display shows input stats IN
HI or IN LO. If set as output, pressing
Enter
toggles the output between HI and LO. OUT HI or OUT
LO.
OUT LO is active.
PORT1
PORT2
TEST
Performs a loopback test on serial port 1 or 2. Connect jumper TX and RX together on port 1 or
port 2 before testing.
Parameter
Choices
Description
Table 3-19.