98
Counterpart Counting Scale Indicator
9.10 Regulatory Mode and Legal-for-Trade (LFT)
Note
When REGULAT is set for NONE or INDUST there are no restrictions on displaying both the weight and piece
count data.
If the unit is going to be used in Legal for Trade applications, weight and piece count data cannot be displayed at
the same time. Use the following examples to use Counterpart in Legal for Trade applications.
9.10.1 Legal for Trade and Normal Weight Mode
When in a Legal for Trade mode (REGULAT = NTEP, OIML, or CANADA) and the unit is in normal weigh mode:
•
If the weight is displayed in the main area (either as a result of the DSPMODE parameter being set for
WEIGHT or the Swap Display softkey was pressed) then the piece count and unit weight are not
displayed.
•
If the piece count is displayed in the main area (either as a result of the DSPMODE parameter being set
for COUNT or the Swap Display softkey was pressed) then the weight is not displayed. The unit
weight will be displayed in the left display area.
•
If the unit weight is displayed in the main area (either as a result of the DSPMODE parameter being set
for UNITWEIGHT or the Swap Display softkey was pressed) then the weight is not displayed. The
piece count will be displayed in the left display area.
CTARE
Allow CLEAR key to clear tare/
accumulator
YES
YES
NO
NO
YES
PRTMOT
Allow print while in motion
NO
NO
NO
NO
YES
PRTPT
Add PT to keyed tare print
NO
NO
YES
YES
NO
OVRBASE
Zero base for overload calculation
CALIB ZERO
CALIB ZERO
CALIB ZERO
SCALE ZERO
CALIB ZERO
REGULAT / INDUST Parameter
REGULAT Mode
Parameter Name
Text Prompt
INDUST
NTEP
CANADA
OIML
NONE
Table 9-6. REGULAT / INDUST Mode Parameters, Comparison with Effective Values of Other Modes (Continued)