1. Drive head with LED
11. Towing attachment to door
3. Rail section - drive side
12. Traction bar
4. Carriage
13. Central attachment for ceiling mountings
7. Rail connector
16a. Iron plates with slotted holes for ceiling mountings on drive head
8. Rail section - door side
16b. Iron plates with slotted holes for ceiling mountings on rail
9. Belt tensioner
17. Mains cable, 1.2 m long
10. Attachment to wall
3.2
Technical data
General informations
Suitable for the following types of doors:
Canopy / non-up-and-over doors, double-leaf doors, up-and-over / tilt doors, sectional doors / side section doors
Max size of the door:
17 m
2
Max weight:
200 kg (sectional door) / 280 kg (up-and-over door)
Model specifications
Nominal Force:
360 N
Max Force:
1200 N
Power supply:
230 V / 50Hz
Power consumption
Stand-by:
< 0,5 W
Max operation:
410 W
Max Cycles / hour.:
3
Max Cycles/day.:
10
Max total Cycles:
25.000
LED light:
1,6 W
Safety according to EN 13849-1
STOP-A input:
cat. 2 / PL “c”
STOP-B input:
cat. 2 / PL “c”
Internal limit force control:
cat. 2 / PL “c”
Operating temperature:
-20 ÷ +60°C
Protection level:
IP20, only for dry environments
Noise level:
< 70 dBA
3.3
Control elements
1
15
A
D
B
C
A1
Fig. 4:
Control elements
A. Numerical display
A1 Digital dot on display
B. OPEN / START button
C. CLOSE button
D. Program button (PROG button)
1. Drive head
15. Radio transmitter (optional)
3.4
Functioning of the integrated safety unit
If the garage door encounters an obstruction during closing, the operator stops and releases the obstruction by opening the door to the upper limit position, see chapter “Force learning cycle”.
If the garage door encounters an obstruction during opening, the drive stops and moves back to release the obstruction. The door can be closed again giving a commmand.
G