60
10.
Set time/tariff control on Master heat pump if required. Refer to
see the chart for navigating the control panel display.
If the water heater is full of cold water, heating will commence unless the flow
rate of the cold side or the temperature of the cold side and hot side is below
the set point, in which case the auxiliary boost will operate, if installed.
It is important to wait for five minutes after the heat pump has activated to
ensure it continues to operate and is functioning correctly.
Note: The water heater may not turn on immediately when it is first switched
on, if it is switched on within 20 minutes to 2 hours of it having been switched
off at the isolating switch, or the heat pump has just completed a heating cycle.
The water heater will wait until the conditions for start-up are favourable in
order to protect the compressor from damage. This may take up to 20 minutes
to 2 hours. The auxiliary booster (if installed) will operate instead of the heat
pump if the temperature or the flow rate of the cold side is below the set point.
Explain to a responsible officer the functions and operation of the heat pump
water heater. Upon completion of the installation and commissioning of the
water heating system, leave this guide with the responsible officer.
Summary of Contents for W2W Series
Page 24: ...INSTALLATION 24 Typical Installation with Recirculation ...
Page 25: ...INSTALLATION 25 Typical Installation with Inline Auxiliary Boost ...
Page 26: ...INSTALLATION 26 Typical Installation with Rheem Guardian Warm Water System ...
Page 27: ...INSTALLATION 27 Dimensions and Technical Data RHEEM W2W Model 15kW 95401500 ...
Page 28: ...INSTALLATION 28 Dimensions and Technical Data RHEEM W2W Model 35kW 95403500 ...
Page 29: ...INSTALLATION 29 Dimensions and Technical Data RHEEM W2W Stackable Model 15kW 9540150S ...
Page 30: ...INSTALLATION 30 Dimensions and Technical Data RHEEM W2W Stackable Model 35kW 9540350S ...
Page 48: ...15KW HEAT PUMP INTERNAL WIRING DIAGRAM ...
Page 49: ...CONNECTIONS ELECTRICAL 49 35KW HEAT PUMP INTERNAL WIRING DIAGRAM ...
Page 50: ...CONNECTIONS ELECTRICAL 50 Controller and Display Information ...