Note:
If no keys are pressed for 60 seconds, screen reverts to main display
screen and any changes made and not confirmed will be lost.
Set Point Quick Setting
Press
‘prg’
from the main display screen and the Set Point page will appear.
Cursor will be on the set temperature. Pressing the up and down keys will
adjust the setting in 0.1 increments. Hold down for rapid change. Press
’Enter’
to confirm change. Press
‘esc’
to return to the main display screen. The
maximum setting is 60⁰C. This will provide up to 65⁰C in the tank.
Menu Item
A.
On/Off
– Press
’ente
r’ to access change. Press
‘up’
or
‘down’
to turn unit
on or off. Press
‘enter’
to confirm.
Press
‘down’
key to display type of circulating pump control.
Default: AUTOMATIC ON TEMP
Press
‘esc’
to return to Menu Master.
B.
Set Point
- displays the tank maximum set point at which the compressor
will be deactivated. Cursor will be on the set temperature. Pressing the
‘
up
’
and
‘
down
’
keys will adjust the setting in 0.1 increments. Hold down for
rapid change. Press
’enter’
to confirm change. Press
‘esc’
to return to the
Menu Master.
C.
Clock / Scheduler
– time and date are set here. Other adjustments
include:
i.
Enable Scheduler:
No (controls heat pump operating time
based on programmed time period)
ii.
Enable Tariff:
No (controls heat pump operating time based
on tariffs)
iii.
Enable D.L. Save:
No (shifts time based on seasons)
Summary of Contents for W2W Series
Page 24: ...INSTALLATION 24 Typical Installation with Recirculation ...
Page 25: ...INSTALLATION 25 Typical Installation with Inline Auxiliary Boost ...
Page 26: ...INSTALLATION 26 Typical Installation with Rheem Guardian Warm Water System ...
Page 27: ...INSTALLATION 27 Dimensions and Technical Data RHEEM W2W Model 15kW 95401500 ...
Page 28: ...INSTALLATION 28 Dimensions and Technical Data RHEEM W2W Model 35kW 95403500 ...
Page 29: ...INSTALLATION 29 Dimensions and Technical Data RHEEM W2W Stackable Model 15kW 9540150S ...
Page 30: ...INSTALLATION 30 Dimensions and Technical Data RHEEM W2W Stackable Model 35kW 9540350S ...
Page 48: ...15KW HEAT PUMP INTERNAL WIRING DIAGRAM ...
Page 49: ...CONNECTIONS ELECTRICAL 49 35KW HEAT PUMP INTERNAL WIRING DIAGRAM ...
Page 50: ...CONNECTIONS ELECTRICAL 50 Controller and Display Information ...