REGULAR CARE
13
TEMPERATURE AND PRESSURE RELIEF VALVE AND EXPANSION
CONTROL VALVE
A temperature and pressure relief valve is supplied with the storage tanks. In
many areas, including South Australia, Western Australia and scaling water
areas, an expansion control valve is also fitted to the cold water line to the water
heater system. The expansion control valve may discharge a small quantity of
water from its drain line during the heating period instead of the temperature
pressure relief valve on the storage tanks.
Operate the easing lever on the temperature and pressure relief valve and
expansion control valve once every six months.
It is very important you raise
and lower the lever gently.
Warning:
Exercise care to avoid any splashing of water, as water
discharged from the drain line will be hot. Stand clear of the drain line’s point of
discharge when operating the valve’s lever.
DANGER:
Failure to do this may result in the water heater heat exchanger
failing.
If water does not flow freely from the drain line when the lever is lifted, then the
water heater must be checked Phone Rheem Service or their nearest Accredited
Service Agent (or Service Centre in NZ) to arrange for an inspection.
The temperature and pressure relief and expansion control valve should be
replaced at intervals not exceeding 5 years, or more frequently in areas where
there is a high incidence of water deposits (refer to
page 14
Summary of Contents for W2W Series
Page 24: ...INSTALLATION 24 Typical Installation with Recirculation ...
Page 25: ...INSTALLATION 25 Typical Installation with Inline Auxiliary Boost ...
Page 26: ...INSTALLATION 26 Typical Installation with Rheem Guardian Warm Water System ...
Page 27: ...INSTALLATION 27 Dimensions and Technical Data RHEEM W2W Model 15kW 95401500 ...
Page 28: ...INSTALLATION 28 Dimensions and Technical Data RHEEM W2W Model 35kW 95403500 ...
Page 29: ...INSTALLATION 29 Dimensions and Technical Data RHEEM W2W Stackable Model 15kW 9540150S ...
Page 30: ...INSTALLATION 30 Dimensions and Technical Data RHEEM W2W Stackable Model 35kW 9540350S ...
Page 48: ...15KW HEAT PUMP INTERNAL WIRING DIAGRAM ...
Page 49: ...CONNECTIONS ELECTRICAL 49 35KW HEAT PUMP INTERNAL WIRING DIAGRAM ...
Page 50: ...CONNECTIONS ELECTRICAL 50 Controller and Display Information ...