31
CLEARANCES- WATER TO WATER HEAT PUMP MODELS
Sides
Unit
All Water to Water Heat Pumps
Front
mm
850
Back
mm
Nil
Water Connections Side
mm
850
RHS Side
mm
Nil
Top (clearance above
unit required for service
personnel to stand)
mm
Nil
HEAT PUMP AND TANK ASSEMBLY
HEAT PUMP AND STORAGE TANKS
The heat pump water heater system is modular and comprises three main
components: the heat pump water heater, storage tanks, and primary circulators.
An auxiliary booster and circulator may also be employed as part of the system.
The water heater must not be operated until all components are assembled.
HEAT PUMP
Locate the heat pump(s) in the appropriate position observing the required
clearances for operation and servicing.
Indoor Installations
To comply with AS1677.2, the minimum room size permissible in relation to the
quantity of refrigerant in the water heater, is 5.6m
3
for per 15kW heat pump and
15.34 m
3
for per 35kW heat pump.
Summary of Contents for W2W Series
Page 24: ...INSTALLATION 24 Typical Installation with Recirculation ...
Page 25: ...INSTALLATION 25 Typical Installation with Inline Auxiliary Boost ...
Page 26: ...INSTALLATION 26 Typical Installation with Rheem Guardian Warm Water System ...
Page 27: ...INSTALLATION 27 Dimensions and Technical Data RHEEM W2W Model 15kW 95401500 ...
Page 28: ...INSTALLATION 28 Dimensions and Technical Data RHEEM W2W Model 35kW 95403500 ...
Page 29: ...INSTALLATION 29 Dimensions and Technical Data RHEEM W2W Stackable Model 15kW 9540150S ...
Page 30: ...INSTALLATION 30 Dimensions and Technical Data RHEEM W2W Stackable Model 35kW 9540350S ...
Page 48: ...15KW HEAT PUMP INTERNAL WIRING DIAGRAM ...
Page 49: ...CONNECTIONS ELECTRICAL 49 35KW HEAT PUMP INTERNAL WIRING DIAGRAM ...
Page 50: ...CONNECTIONS ELECTRICAL 50 Controller and Display Information ...