ELECTRONIC AIR CLEANER
Line voltage power can be supplied from the terminal la-
beled “EAC” and a line voltage neutral terminal on the
control board. This will power the electronic air cleaner
whenever the circulating air blower is in operation.
NOTE:
The electronic air cleaner output will not be ener-
gized when the ECM blower motor target CFM is below
the following thresholds:
(-)96V040 = 500 CFM
(-)96V060 = 500 CFM
(-)96V070 = 500 CFM
(-)96V085 = 600 CFM
(-)96V100 = 600 CFM
(-)96V115 = 600 CFM
Under some cirumstances, such as low-speed continuous
fan, the target blower CFM may be below the above
threshold. In these cases the electronic air cleaner output
will NOT be energized.
NOTE:
Maximum current is 1.0 amps for the electronic air
cleaner output.
HUMIDIFIER
Humidifier output is a set of dry contacts. The logic control-
ling these contacts and the necessary wire diagrams for in-
stalling a humidifier are detailed in the section of this
manual titled
Humidification/Dehumidification
.
FILTERS
(See Figure 42)
Keep filters clean at all times.
A filter is not provided
with the furnace, but one must be field-supplied and
installed.
It is recommended to replace the furnace filter periodically
to maintain optimum furnace performance.
TWINNING
Twinning of these furnaces is NOT permitted!
ACCESSORIES
FIELD INSTALLED OPTION ACCESSORIES
Summary of Contents for 96MDV Series
Page 34: ...Field Conversions 34...
Page 35: ...Field Conversions 35...
Page 36: ...36 Field Conversions...
Page 37: ...37 Field Conversions...
Page 38: ...Field Conversions 38...
Page 115: ...115 TABLE 20 continued R96V FAULT CODES WITH DESCRIPTIONS AND SOLUTIONS Diagnostics...
Page 120: ...120 Diagnostics TABLE 20 continued R96V FAULT CODES WITH DESCRIPTIONS AND SOLUTIONS...
Page 126: ...126 FIGURE 65 2 STAGE ECM FURNACE WIRING DIAGRAM Troubleshooting...
Page 127: ...127...
Page 128: ...128 CM 1015...