Fi
el
d
Co
nv
er
sio
ns
PARTS NEEDED:
PARTS NEEDED FOR THIS CONVERSION REQUIRE ITEMS
FROM THE
PARTS BAG
AND CONVERSION KIT
RXGY-CK.
YOU MUST HAVE THE PARTS OUTLINED BELOW BEFORE PROCEEDING.
!
NOTE: STEPS 1- 5 SHOWN WITH FURNACE IN “AS SHIPPED CONDITION”
NOTE: THESE CONVERSION INSTRUCTIONS ARE INTENTIONALLY GENERIC, SOME PARTS MAY BE DIFFERENT IN YOUR FURNACE
HORIZONTAL RIGHT / RIGHT VENT
ST-A1194-32-01
2
2a - RELOCATE 1/2" VINYL CAP (YELLOW) ON THE
INDUCER COUPLING
2b - RELOCATE THE .403" DRAIN PLUG IN THE
COLLECTOR BOX.
2c - RELOCATE 1/4" VINYL CAP (YELLOW) ON
COLLECTOR BOX VENT TAP.
2a
2b
2c
MOVE
MOVE
MOVE
1
1a - REMOVE TRAP AND HOSES
(NOTE: TO REMOVE TRAP, REMOVE (2) SCREWS
AND PULL STRAIGHT OUT)
1b - INSTALL INTAKE COUPLING IN TOP PLATE
AS SHOWN.
1a
1b
HOSE “D” (DISCARD)
VENT HOSE (DISCARD)
DRILL
1/8" DRILL BIT
PLIERS
FLAT HEAD SCREWDRIVER
5/16 HEX HEAD DRIVER
1/4" HEX HEAD DRIVER
TOOLS/MATERIALS NEEDED:
CONDENSATE
TRAP GASKET
.559 DRAIN PLUG
#8 X 1/2"
SCREW
(X3)
1/4" BLACK
VENT TUBE
1/2" DRAIN
HOSE E
1/2" DRAIN
HOSE F
FROM CONVERSION KIT RXGY-CK
INTAKE
COUPLING
AND NUT
FROM PARTS BAG
(PROVIDED WITH UNIT)
AIRFLOW
PARTS NEEDED FOR THIS CONVERSION REQUIRE ITEMS
FROM THE
PARTS BAG
AND CONVERSION KIT
RXGY-CK.
YOU MUST HAVE THE PARTS OUTLINED BELOW BEFORE PROCEEDING.
28
Summary of Contents for 96MDV Series
Page 34: ...Field Conversions 34...
Page 35: ...Field Conversions 35...
Page 36: ...36 Field Conversions...
Page 37: ...37 Field Conversions...
Page 38: ...Field Conversions 38...
Page 115: ...115 TABLE 20 continued R96V FAULT CODES WITH DESCRIPTIONS AND SOLUTIONS Diagnostics...
Page 120: ...120 Diagnostics TABLE 20 continued R96V FAULT CODES WITH DESCRIPTIONS AND SOLUTIONS...
Page 126: ...126 FIGURE 65 2 STAGE ECM FURNACE WIRING DIAGRAM Troubleshooting...
Page 127: ...127...
Page 128: ...128 CM 1015...