105
Co
m
m
un
ica
tin
g F
urn
ace
INTEGRATED FURNACE CONTROL
THERMOSTAT WIRING DIAGRAMS-HEAT PUMP
19. 24VAC AND COMMON CONNECTIONS (E10/E11)
For connection to the low voltage side of the control
transformer. Terminals are ¼” quick-connect style.
20. FUSE (P100/P101)
A fuse is provided to protect low-voltage (24VAC) cir-
cuits from shorts between 24VAC and Ground or
Common. A fault code 30 is displayed at the furnace
control when the fuse has been opened.
D
TWO-STAGE
THERMOSTAT
(NON-COMMUNICATING)
TWO-STAGE
GAS
FURNACE
CONTROL
OUTDOOR
UNIT
FIGURE 59
WIRING DIAGRAM FOR A LEGACY TWO-STAGE THERMOSTAT
ST-A1194-93-00
Summary of Contents for 96MDV Series
Page 34: ...Field Conversions 34...
Page 35: ...Field Conversions 35...
Page 36: ...36 Field Conversions...
Page 37: ...37 Field Conversions...
Page 38: ...Field Conversions 38...
Page 115: ...115 TABLE 20 continued R96V FAULT CODES WITH DESCRIPTIONS AND SOLUTIONS Diagnostics...
Page 120: ...120 Diagnostics TABLE 20 continued R96V FAULT CODES WITH DESCRIPTIONS AND SOLUTIONS...
Page 126: ...126 FIGURE 65 2 STAGE ECM FURNACE WIRING DIAGRAM Troubleshooting...
Page 127: ...127...
Page 128: ...128 CM 1015...