![Rheem 96MDV Series Installation Instructions Manual Download Page 77](http://html1.mh-extra.com/html/rheem/96mdv-series/96mdv-series_installation-instructions-manual_1451387077.webp)
77
5. Move the junction box to the opposite side of the cabi-
net. Install using the two screws removed in step 3
above. Note that all screws penetrating the junction
box must be blunt – no sharp tipped screws can be
used.
6. Replace the plug from the opposite of the furnace (the
new j-box location) to the old j-box location and install
qty=2 1/4” plugs from parts bag in empty screw holes
in old location of j-box into the mounting screw holes
in the old junction box location.
7. Using a flat screwdriver, squeeze the retaining arms
on the door switch and gently pry the door switch from
it’s opening as shown in Figure 39.
8. Install the door switch in the same opening on the op-
posite of the furnace and reconnect the electrical con-
nectors (removed in Step 2) to the door switch.
THERMOSTAT
The room thermostat must be compatible with the furnace.
See manufacturer’s thermostat spec sheet for compatibil-
ity concerns. Generally, all thermostats that are not of the
“current robbing” (“current robbing” thermostats require the
addition of an isolation relay. See Figure 41) types are
compatible with the integrated furnace control. The low
voltage wiring should be sized as shown.
NOTE:
Do not use 24 volt control wiring smaller than No.
18 AWG.
Install the room thermostat in accordance with the instruc-
tion sheet packed in the box with the thermostat. Run the
thermostat lead wires inside the blower compartment and
connect to low voltage terminals as shown on the wiring
diagram. Never install the thermostat on an outside wall or
where it will be influenced by drafts, concealed hot or cold
water pipes or ducts, lighting fixtures, radiation from fire-
place, sun rays, lamps, televisions, radios or air streams
from registers.
ELECTRICAL WIRING
REVERSING ELECTRICAL CONNECTION & THERMOSTAT
Ele
ctri
ca
l W
irin
g
HEAT COOL FAN
M2 M1 H/C
EAC L1B XFMR HUM
SPARK
IGNITION
TOWER
NEUTRALS
LINE
P2
ST-A1194-26-X0
FIGURE 40
LINE VOLTAGE CONNECTIONS
ST-A1194-59-00
ST-A1194-59
FIGURE 41
ISOLATION RELAY
Summary of Contents for 96MDV Series
Page 34: ...Field Conversions 34...
Page 35: ...Field Conversions 35...
Page 36: ...36 Field Conversions...
Page 37: ...37 Field Conversions...
Page 38: ...Field Conversions 38...
Page 115: ...115 TABLE 20 continued R96V FAULT CODES WITH DESCRIPTIONS AND SOLUTIONS Diagnostics...
Page 120: ...120 Diagnostics TABLE 20 continued R96V FAULT CODES WITH DESCRIPTIONS AND SOLUTIONS...
Page 126: ...126 FIGURE 65 2 STAGE ECM FURNACE WIRING DIAGRAM Troubleshooting...
Page 127: ...127...
Page 128: ...128 CM 1015...