INTEGRATED FURNACE CONTROL
THERMOSTAT WIRING DIAGRAMS-CONDENSING UNIT
19. 24VAC AND COMMON CONNECTIONS (E10/E11)
For connection to the low voltage side of the control
transformer. Terminals are ¼” quick-connect style.
20. FUSE (P100/P101)
A fuse is provided to protect low-voltage (24VAC) cir-
cuits from shorts between 24VAC and Ground or
Common. A fault code 30 is displayed at the furnace
control when the fuse has been opened.
TWO-STAGE
THERMOSTAT
(NON-COMMUNICATING)
TWO-STAGE
GAS
FURNACE
CONTROL
CONDENSER
UNIT
FIGURE 56
WIRING DIAGRAM FOR A LEGACY TWO-STAGE THERMOSTAT
ST-A1194-62-03