OPEN: output is open after powerup/reboot
CLOSE: output is close after powerup/reboot
LAST: keep the previous state after powerup/reboot
Please be aware that a device reboot will affect the output state
because output will become open during booting process.
(SMS Control) Function:
the option to enable the SMS control of the
output. Disabled by default.
CLSOE Message:
User-defined SMS command to close the output.
OPEN Message:
User-defined SMS command to open the output.
PULSE Message:
User-defined SMS command to output a pulse.
Report Group:
the contact group that can send output control SMS
commands. Disabled by default.
(Remote Control) Function:
the option to allow the output to be
controlled by a remote device. Disabled by default.
Secured Remote Control:
the option to require a secured IP
communication for the remote IO control/automation. The TLS with a
pre-shared key is used to encrypt the communication.
Pre-shared Key:
the pre-shared key used for the secured remote
control.
(Output Schedular) Function:
the option to enable the function that only
allows the device output to be controlled (locally or remotely) during a
pre-defined period. Outside the time frame, the output state will remain
the last state unchangeable until the next schedule time.
A Cron expression with five(5) space-separated fields is used for the
schedule settings. The definitions of each field are:
Minute Hour DayofMonth Month DayofWeek
For example, if the output is to be controlled during 8AM to 6PM in a
day from Monday to Friday, a Cron expression can be set as: