The IO automation is achieved by executing automation rules saved in
the rules table. Each rule will have Site Address, Input Index, ON Action,
and OFF action. Up to ten(10) rules can be set up for each input.
Site Address:
the IP or URL of the remote device whose output is to be
controlled by the input.
Secured Remote Control:
the option to enable the secured
communication for the IO automation if the remote device requires it.
A pre-shared key will be required. Disabled by default.
ON/OFF Action:
the action to take when input is in ON and OFF state.
The output index and action (OPEN, CLOSE, or PULSE) will be defined in
the action and saved in the rule table below.
OUTPUT 0 / 1
The Output page provides the configuration options for the digital outputs.
Power On State:
defines the output state after powerup or reboot: