60
3.
Once the fuse holder is in place, don’t attach a fuse just yet. Connect the bare stranded
portion of the cable to the
positive (+)
battery terminal on the charge controller.
4. The
fuse between controller and battery should be the current rating of the
controller.
Once the fuse is properly sized, ensure that all connections were made
properly, and that there are no loose connections present. Finally, insert the fuse into the
fuse holder.
The controller should power on.
5. If opting for
no in-line fuse
, connect the bare stranded portion of the cable to the
positive
(+)
battery input terminal on the charge controller directly from the
positive (+)
battery
post, bypassing the fuse holder.
The controller should power on.
Warning!
Be careful not to short the battery. Reverse polarity connection will
damage the charge controller and the resulting damage will not be covered
by warranty.
Maxi blade fuse
Controller to Battery Fuse = Current Rating of Charge
Controller
Ex. 30A ViewStar CC = 30A from Controller to Battery
Summary of Contents for Off-Grid Kit
Page 8: ...8 Wiring 1 Unscrew battery terminals and connect battery connections...
Page 10: ...10 4 Insert battery remote sensor block terminal and connect wires POLARITY SENSITIVE...
Page 16: ...16...
Page 17: ...17 Repeat for each Z Bracket in the set at each corner...
Page 18: ...18...
Page 20: ...20...
Page 21: ...21 NOTE Orient panel in level plumb layout as desired before fixing in position...
Page 23: ...23 Repeat for all brackets NOTE Seal around all edges of bracket and screws...
Page 27: ...27...
Page 29: ...29 NOTE Orient panel in level plumb layout as desired before fixing in position...
Page 36: ...36 NOTE Start lag bolt threading by hand...
Page 37: ...37 Rail System Construction 2 1...
Page 38: ...38 4 3...
Page 39: ...39 6 5...
Page 40: ...40 Repeat for all continuous rail sets Rail Seating 7 1...
Page 41: ...41 3 2...
Page 42: ...42 5 4...
Page 44: ...44 3 2...
Page 45: ...45 5 4 NOTE Ensure that the End Clamp is spaced a minimum distance of 1 25 from rail end face...
Page 46: ...46 Continue mid clamp procedure for each additional panel 6 7...
Page 55: ...55 Figure 7 Figure 8...