RL78/G1P
CHAPTER 11 SERIAL ARRAY UNIT
R01UH0895EJ0100 Rev.1.00
364
Nov 29, 2019
(3) Processing flow (in single-transmission/reception mode)
Figure 11-44. Timing Chart of Master Transmission/Reception (in Single-Transmission/Reception Mode)
(Type 1: DAPmn = 0, CKPmn = 0)
Receive data 1
Receive data 2
Receive data 3
SSmn
SEmn
SDRmn
STmn
SCKp pin
SIp pin
Shift register mn
INTCSIp
TSFmn
SOp pin
Data transmission/reception
Data transmission/reception
Data transmission/reception
Transmit data 3
Transmit data 2
Transmit data 1
Reception & shift operation
Reception & shift operation
Reception & shift operation
Receive data 3
Receive data 2
Receive data 1
Transmit data 3
Transmit data 2
Transmit data 1
Write
Read
Read
Write
Write
Read
Remark
m: Unit number (m = 0), n: Channel number (n = 0), p: CSI number (p = 00), mn = 00