RL78/G1P
CHAPTER 11 SERIAL ARRAY UNIT
R01UH0895EJ0100 Rev.1.00
355
Nov 29, 2019
(3) Processing flow (in single-reception mode)
Figure 11-36. Timing Chart of Master Reception (in Single-Reception Mode)
(Type 1: DAPmn = 0, CKPmn = 0)
Receive data 3
Receive data 2
Receive data 1
Dummy data for reception
Dummy data
Dummy data
Receive data 1
Receive data 2
Receive data 3
SSmn
SEmn
SDRmn
STmn
SCKp pin
SIp pin
Shift register mn
INTCSIp
TSFmn
Data reception
Data reception
Data reception
Reception & shift operation
Reception & shift operation
Reception & shift operation
Write
Read
Read
Read
Write
Write
Remark
m: Unit number (m = 0), n: Channel number (n = 0), p: CSI number (p = 00), mn = 00