RL78/G1P
CHAPTER 11 SERIAL ARRAY UNIT
R01UH0895EJ0100 Rev.1.00
416
Nov 29, 2019
Figure 11-88. Procedure for Resuming Slave Reception
Disable clock output of the target channel by
setting a port register and a port mode register.
Port manipulation
Starting setting for resumption
Changing setting of the SPSm register
Changing setting of the SMRmn register
Changing setting of the SCRmn register
Clearing error flag
Completing resumption
setting
Re-set the register to change the operation clock
setting.
Re-set the register to change serial mode register
mn (SMRmn) setting.
Re-set the register to change serial communication
operation setting register mn (SCRmn) setting.
If the OVF flag remains set, clear this
using serial flag clear trigger register mn
(SIRmn).
(Essential)
(Selective)
Writing to the SSm register
(Selective)
(Selective)
(Selective)
(Essential)
Set the SSmn bit of the target channel to 1
(SEmn bit = 1: to enable operation). Wait
for a clock from the master.
Completing master
preparations?
No
Wait until stop the communication target (master)
or operation completed.
Yes
(Essential)
Port manipulation
Writing to the ISC register
Enable clock output of the target channel by setting
a port register and a port mode register.
Set the SSIE00 bit to 1 and enable slave select
function operation of channel 0.
(Essential)
(Essential)
Remark
m: Unit number (m = 0), n: Channel number (n = 0), p: CSI number (p = 00)