Cautions 4. In hardware trigger wait mode, make settings that affect the conversion time such that the following
conditions are satisfied.
f
AD
must be in the range from 1 to 16 MHz.
When the setting of the ADISS bit of the ADS register is 1, selecting the temperature sensor or
internal reference voltage output, the following condition applies.
Setting LV0 to 0 is prohibited.
Only setting LV0 to 1 is permitted.
Remark
f
CLK
: CPU/peripheral hardware clock frequency