45
1
2
Gas
230 V
2x
1. Open the boiler
LT.AL.W7H.000.058
•
Isolate the 230 V supply at the switched spur and remove
the fuse
•
Isolate the gas supply at the boiler gas valve
•
Remove the front panel (release the two screws at the bot-
tom of the front panel, pull the bottom of the panel forward
and lift off the two pins on the top of the main casing).
2. Maintenance of the ignition/ionisation electrode
LT.AL.W7H.000.059
•
Disconnect the earth wire from the electrode mounting
plate.
•
Release the two screws on the electrode and remove the
assembly.
•
Inspect, clean re-gap or replace the electrode,
see par
3.1.3
.