20
Remeha Avanta Plus
1
2
Manufacturer
Sit Controls
Supply voltage
230 V – 1ph – 50 Hz
Pre-purge time
3 s
Post-purge time
5 s
Ignition time
2.5 s
Safety time
5 s
Anti-cycling time
3 till 10 min.
Fuse value F1 (230 V)
2 AT
DC fan (for 24s, 35c and 28c)
24 VDC
AC fan (for 39c only)
230 VAC
table 04 Control unit characteristics
m
Any loads other than those specified above are only allowed if
an isolating transformer is used.
The output of the Remeha Avanta Plus can be controlled in
the following ways:
On/off control – volt free switching -
The boilers internal
control will modulate the output to achieve the flow tempera-
ture set point of the boiler. This contact is on the X9 terminal
strip (low voltage only).
Modulated control – Open Therm -
The external controls will
modulate the boiler’s output to achieve the flow temperature
determined by the modulating regulator. This contact is on the
X9 terminal strip (low voltage only).
On/off control – 230 V switching -
The boilers internal con-
trol will modulate the output to achieve the flow temperature
set point of the boiler. This contact is on the X2 terminal strip
(230 VAC only).
Modulated control – Open Therm in combination with an
externally mounted simple 230 V switching time clock -
The boiler will provide room compensated heating and time
control over CH and DHW (System boiler).
z
• All connections on terminal X1, X2, X4, X5, X6 and X7 are
230
VAC.
• All connections on terminal X9 are low voltage only.
2.7 Connecting external controls
•
Release the two screws at the bottom of the front casing
and remove the front casing.
•
Feed the cables through the grommet in the base of the
boiler.
•
Connect the cables to the relevant connectors, as shown in
the diagrams.
LT.AL.W7H.000.024
{
•
Isolate power supply at the fused spur before carrying out
any work on the boiler controls.
Summary of Contents for Avanta Plus 24s
Page 94: ...30...
Page 95: ...31...
Page 97: ...2 AVANTA PLUS 28 Combi Gas Council No 47 673 02 39 Combi Gas Council No 47 673 04...
Page 100: ...5...
Page 104: ...9...
Page 107: ...12 AVANTA PLUS 24 System Gas Council No 41 288 05...
Page 110: ...15...