ENABLING THE BOILER
LT.AL.W7H.000.211
LTALW7H000211a
1,5 ... 2 bar
•
Check the boiler water pressure. If the water pressure
is less than 1 bar, the system has to be topped up
with water,
see par.
5.1
.
LT.AL.W7H.000.223
LTALW7H000223a
R
•
Switch on the boiler at the fused spur unit; the boiler will
run the start-up program.
- A display test will briefly appear showing all segments of
the display.
f[ xx
software version;
p[ xx
parameter version;
- A venting cycle of 2 minutes now follows, the version
numbers will be displayed alternately;
- Next, the following will appear in the display;
[1
; boiler is ventilating;
[2
; boiler is igniting;
[4
; boiler is operating for DHW;
[7
; boiler pump is running after heating DHW;
[0
; boiler is stand-by.
LT.AL.W7H.000.212
LTALW7H000212a
•
Set the room thermostat to the desired room temperature.
The boiler will now automatically start operating.
See par.
3.2
for an explanation of the codes on the display.
LT.NL.W6H.000.079
R
LTNLW6H000079A
Error message
If the boiler does not start operating and an error message is
displayed, consult the error table in
par.
4.1
and, if necessary,
consult the installer.