8
Remeha Avanta Plus
LTNLW6H000070A
R
•
Press the
[+]
key again until
t4
appears and, for exam-
ple,
18
(18°C), the current outside temperature;
•
Press
[+]
key again until
f
l
appears and e.g.
^0
(6uA), the present ionisation current;
•
Press
[+]
key again until
ñf
appears and e.g.
30
(3000 rpm), the present fan speed;
•
Press
[+]
key
again and the read-out cycle will start again
with
t1
, etc.;
•
Press
‘Reset’- key
to return to the display with the cur
rent operating status.
3.3
Changing settings
The user can change the following settings:
p
1
Maximum flow temperature (= water temperature that
leaves the boiler) [°C], adjustable between 20 and 85°C
(factory setting = 75°C)
p
2
Maximum domestic hot water temperature [°C], adjust-
able between 40 and 65°C (factory setting = 55°C)
p
3
Boiler regulation; central heating and domestic hot water
mode adjustable at four levels:
0 = central heating OFF and domestic hot water OFF
1 = central heating ON and domestic hot water ON
(= factory setting)
2 = central heating ON and domestic hot water OFF
3 = central heating OFF and domestic hot water ON
p
4
Eco or comfort mode adjustable at 3 levels:
0 = comfort setting
1 = eco mode
2 = regulated by controller (= factory setting)
p
5
Anticipated current for on/off thermostat (ask your ser-
vice engineer for further details)
0 = no anticipated current (= factory setting)
1 = anticipated current
p
6
Display off automatically
0 = display stays off
1 = display stays on
2 = display switches off automatically after 3 minutes
(= factory setting)
Changing P1 setting: flow temperature of water in central
heating system
LT.NL.W6H.000.070
Reduce the flow temperature as follows:
•
Press
‘Enter’- key
until codes
p
[
and
[
1
are dis-
played alternately.
•
Press
‘Enter’- key
again; set value for maximum flow
temperature is displayed: 75°C (factory setting).
•
Press
[+]
or
[-] -key
to change this value, for example to
70°C.
•
Press
‘Enter’- key
to confirm value; codes
p
[
and
[
1
are displayed alternately.
•
Press
‘Reset’- key
to switch boiler to operating mode.
Summer holidays
In summer a reduced flow temperature setting may be ade
quate for your heat requirement. Reduce the flow temperature
and save energy.