35
R
o
•
If the boiler is set to the economy setting (see par. 2.9.8),
it will not supply a boost to DHW after CH is satisfied. The
display then shows; [1 ; pre-purge stage [6 ; pump run on
after CH [0 ; stand-by mode.
•
If a two channel time clock is fitted and connected to a
combi boiler and the time control for DHW is in the “OFF”
position, the DHW production will be disabled unless the
link between connectors 2 and 3 on the X2 terminal is fitted
(normally factory fitted).
2.9.6
Read out settings
The following settings can be read out in the ‘user menu’:
-
t1
= flow temperature [°C];
-
t2
= return temperature [°C];
-
t3
= boiler temperature [°C];
-
t4
= outside temperature [°C];
-
fl
= ionisation current [
u
A];
-
ñf
= fan speed [rpm] ;
LT.AL.W7H.000.046
•
Press the
[+]
key, until
t1
appears and, for example,
68
(68°C), the current flow temperature;
•
Press the
[+]
key again until
t2
appears and, for exam-
ple,
45
(45°C), the current return temperature;
•
Press the
[+]
key again until
t3
appears and, for exam-
ple,
50
(50°C), the current boiler temperature;
•
Press the
[+]
key again until
t4
appears and, for exam-
ple,
18
(18°C), the current outside temperature;
•
Press
[+]
key again until
f
l
appears and e.g.
^0
(6uA),
the present ionisation current;
•
Press
[+]
key again until
ñf
appears and e.g.
30
(3000
rpm), the present fan speed;
•
Press
[+]
key
again and the read-out cycle will start again
with
t1
, etc.;
•
Press
[reset]
key to return to the display with the current
operating status.