If a cleaning operation becomes necessary, please proceed as
follows:
•
Turn off the mains cold water supply and drain off the resid-
ual DHW;
•
Release two socket head screws and remove plate heat
exchanger;
•
Clean plate heat exchanger with scale solvent (e.g. citric
acid, pH 3); a special cleaning tool (optional accessory) can
be used;
•
Thoroughly cleaning afterwards with clean water;
•
Remove non return valve with filter from on the right hand
side of the hydro block and also clean with the scale sol-
vent; afterwards thoroughly cleaning with clean water.