C O PYR I G HT © 2 0 1 7 R ED.C O M , LLC
9 5 5 - 0 0 4 4 , R EV - H
|
5 3
RED 3-AXIS SYSTEM OPERATION GUIDE
CHAPTER 8:
TROUBLESHOOT THE SYSTEM
GENERAL TOPICS
W.M.D. SHUTDOWN
SYMPTOM
The Wireless Motor Driver (W.M.D.) shuts off while driving multiple motors on a stiff lens.
EXPLANATION
The 12 V auxiliary (AUX) port(s) on many camera power modules, including the REDVOLT
®
XL Module, provide a
maximum of 3.8 A of current and is sufficient for most operating conditions. In certain instances, when driving multiple
motors simultaneously on a stiffer than normal lens, the W.M.D. may draw more than 3.8 A. The event may cause an
interruption of power supplied to the W.M.D. and result in a shutdown.
POTENTIAL RESOLUTIONS
Connect the W.M.D. to a 12 VDC power source with sufficient amperage.
Unplug a motor that is not being used for a particular shooting sequence.
Select
Low Power
mode.
NOTE:
Low Power mode may affect performance when maximum power is required.
POWER FAILURE
SYMPTOM
The camera monitor displays an error message stating that a Rear Battery Power and Fault has occurred and too
much current has been drawn from the camera, resulting in the port ceasing to provide power.
EXPLANATION
The camera notifies the you and removes power from that port. Power failure occurs when the W.M.D. attempts to use
more power than the camera module can provide. For example, driving multiple motors on very stiff lenses can cause
power failure.
POTENTIAL RESOLUTIONS
Connect the W.M.D. to a 12 VDC power source with sufficient amperage.
Select
Low Power
mode.
NOTE:
Low Power mode may affect performance when maximum power is required.