107
next step, carefully wash only the
inside of the combustion chamber “H”
of Figure 16-7, and do not get water on
the outside of the combustion chamber
opening. Failure to comply with this
warning can cause extensive property
damage, severe personal injury or death!
16.- Using only water, wash the inside of the
combustion chamber, detail “H” in Figure 16-
7. The water, will drain into the condensate
drain;
17.- Replace gasket “M” as per Figure 16-5
(Part number for this gasket is in Section
18). Take care that the gasket and its site are
clean.
WARNING!!!
Pay attention to
the gasket “M” (Figure 16-5) during
reassemble. When finished, perform
a leakage test with the burner firing.
Always use an approved leak detection
method. Failure to comply with this
warning can cause fire, extensive
property damage, severe personal injury
or death!
18.- Reassemble the components by
proceeding in reverse order. Pay attention
in the reinstalling of gasket between nut “H”
of Figure 16-5 and of the o-ring “L” of Figure
16-6. These must be in good condition. If not
they must be replaced with;
19.- Open the manual gas shutoff valve;
20.- Check that there are no gas leaks;
WARNING!!!
Never use an open
flame to test for gas leaks. Always use
an approved leak detection method.
Failure to comply with this warning can
cause fire, extensive property damage,
severe personal injury or death!
21.- Restore electrical power to the appliance.
16 - MAINTENANCE
A
H
M
020010.01.020
Figure 16-5
- Nut and spring
that fixes the gas valve
Figure 16-6
- Remove the
gas valve
L C
B
020010.01.021
020022.01.008
NO
YES