Appliance MODEL
199
Category of discharge chimney
II and IV
Maximum heat input
Btu/hr
199,500
Minimum heat input
Btu/hr
50,000
Turndown ratio
4:1
Number of burners
1
Gas flow rate (Natural gas)
ft3/hr
199.5
Gas flow rate (LP gas)
ft3/hr
80
Min / Max gas pressure (Nat. and LP)
In.W.C.
3 / 13
Min / Max water temperature
°F
68 / 180
Min / Max water pressure
PSI
8 / 160
Minimum water flow with motorized valves
GPM
11
Minimum water flow without motorized valves
GPM
11
Content of water
gal
1.7
Supply voltage / Frequence
120Vac 60Hz
Absorbed electric power
W
110
Air intake / Flue gas pipes diameter
inch
3
Max. length venting system
ft
120
CO (Carbon monoxide) with natural gas
ppm
<150
CO (Carbon monoxide) with LP gas
ppm
<250
NOx (0% O2 with natural gas)
ppm
<30
CO2 (Carbon dioxide) for Natural gas at high fire
%
8.4 to 8.7
CO2 (Carbon dioxide) for Natural gas at low fire
%
8.4 to 8.7
CO2 (Carbon dioxide) for LP gas at high fire
%
9.5 to 10
CO2 (Carbon dioxide) for LP gas at low fire
%
10.5 to 11.5
O2 (Oxygen) for Natural gas at high fire
%
5.9 to 5.4
O2 (Oxygen) for Natural gas at low fire
%
5.9 to 5.4
O2 (Oxygen) for LP gas at high fire
%
6.4 to 5.6
O2 (Oxygen) for LP gas at low fire
%
4.8 to 3.4
Ionisation current
uA (Micro Amps)
4 to 7
Maximum flue gas temperature
°F
203
Max. negative pressure allowed in the fumes
exhaust/intake system
InWC
0.2
Maximum water condensate flow
GPM
0.032
Average acidity of condensation
PH
4
Appliance weight (empty of water)
lb
211
Recovery Rating (100°F rise)
Gal/hr
227
DHW delivery (75°F rise)
GPM
5