INSTALLATION MANUAL
–
RAVAS-
SafeLoad
33
7.5
Checking the parameters audit trail number for registration (recommended)
Power up the truck to start the RAVAS-SafeLoad indicator.
The buzzer (if activated) will beep shortly and the display will show in the following order; all
segments on/green backlight on/all LEDs of the LED-bar on, the software version with red
backlight and the present weight.
NOTE: if the truck is within an alarm situation the buzzer will sound.
Press and hold the CE-key for 5 seconds.
o
The display will show [PASS.?]
Press
the
-key shortly.
o
The display will show [000
0
] with the most right digit blinking.
Enter the passcode by using the
↑
-key, the
↓
-key and the
-key.
o
If the wrong passcode was entered the display will shortly show [CdErr] and next
return to the previous step; [PASS.?]
o
If the right passcode was entered the display will show [Wght]
For entering the weight parameters press the
-key shortly.
o
The display will show [P_000].
Press
the
↑
-key shortly to enter the parameter selection mode.
o
The display will show [P_00
1
] with the most right digit blinking.
Select parameter 072 by using the
↑
-key, the
↓
-key and the
-key.
o
The display will show the audit trail number for the parameters.
o
Write down this audit trail number if needed.
Press the CE-key if you want to leave the settings menu and return to the weigh
mode.
o
The display will show [Wght].
Press the CE-key again to leave the settings menu and return to the weigh mode.