INSTALLATION MANUAL
–
RAVAS-
SafeLoad
28
7.
Parameter settings
7.1. Parameter setting mode
Power up the truck to start the RAVAS-SafeLoad indicator.
The buzzer (if activated) will beep shortly and the display will show in the following order; all
segments on, the software version and the present weight.
NOTE: if the truck is within an alarm situation the buzzer will sound.
Press and hold the CE-key for 10 seconds.
o
The display will show [PASS.?]
Press
the
-key shortly.
o
The display will show [000
0
] with the most right digit blinking.
Enter the passcode by using the
↑
-key, the
↓
-key and the
-key.
o
If the wrong passcode was entered the display will shortly show [CdErr] and next
return to the previous step; [PASS.?]
o
If the right passcode was entered the display will show [Wght]
For entering the weight parameters press the
-key shortly.
o
The display will show [P_00
0
] with the most right digit blinking.
See weight parameters list.
Or
For entering the moment parameters press the
↑
-key shortly.
o
The display will show [ Mom].
Press
the
-key shortly for activating the parameter menu.
o
The display will show [P_00
0
] with the most right digit blinking.
See moment parameter list.
7.2. Weight parameters
o
The display will show [P_00
0
] with the most right digit blinking.
Press
the
↑
-key shortly to change the parameter selection.
o
The display will show [P_00
1
] with the most right digit blinking.
Select the proper parameter by using the
↑
-key, the
↓
-key and the
-key.
See next page for all possible settings.