INSTALLATION MANUAL
–
RAVAS-
SafeLoad
31
7.4. LED bar, logging and backlight parameters
Use these parameters if changes need to be made in regards to the overload registrations
and warnings, the moment of the LED’s becoming active, switching of relais and/or buzzer,
color of the backlight and logging of events. For most systems the default settings will suffice.
o
While the display shows [P_00
0
] with the most right digit blinking, either from
Moment parameters or Weight parameters.
Press
the
↑
-key shortly to change the parameter selection.
o
The display will show [P_00
1
] with the most right digit blinking.
Select the proper parameter by using the
↑
-key, the
↓
-key and the
-key.
This section of the parameter setting starts with P101 and ends at P111. Each
parameter has several options to be set. See list underneath.
Rules parameters
Parameter Function
Default
Settings
101
green led 1/buzzer/backlight -10/off/off/green/off/off
See table above
102
green led 2/buzzer/backlight 20/off/off/green/off/off
See table above
103
green led 3/buzzer/backlight 40/off/off/green/off/off
See table above
104
green led 4/buzzer/backlight 60/off/off/green/off/off
See table above
105
yellow led 1/buzzer/backlight 85/off/off/green/off/off
See table above
106
yellow led 2/buzzer/backlight
100/off/off/green/off/off
See table above
107
red led 1/buzzer/backlight 110/on/on/red/off/off
See table above
108
red led 2/buzzer/backlight
125/on/on/red/on/on
See table above
109
Activation buzzer/backlight 95/puls/puls/green/off/off
See table above
110
Activation buzzer/backlight
110/on/on/red/on/on
See table above
111
Activation buzzer/backlight
125/on/on/red/on/on
See table above
112
Threshhold value reset event
4%
0%-100% of max capacity
113
Dynamic peak activation value
30%
0%-100% of max capacity
114
Reset dynamic event
±2%
±0%-100% of max capacity
200
Activate error messages for
new version hardware
(implementation Juli 2017)
Off On/Off
201
For internal use only(changing
this setting could cause errors
in normal weighing mode)
Off On/Off
Activation
overload
messages
based
on:
moment
sensor
signal
[LED
bar
functions
and
backlight
functions]
oil
pressure
sensor
[only
backlight]
Function
Settings
P101
P102
P103
P104
P105
P106
P107
P108
P109
P110
P111
Start
‐
10
20
40
60
85
100
110
125
95
110
125
start
point
LED
in
%
of
FS
‐
10%
to
150%
Relay
off
off
off
off
off
off
on
on
off
on
on
Relay
setting
off/puls/on
Buzz
off
off
off
off
off
off
on
on
off
on
on
Buzzer
setting
off/puls/on
Light
green
green
green
green
green
green
red
red
green
red
red
Backlight
setting
green/red
Oload
off
off
off
off
off
off
off
on
off
on
on
Overload
in
display
off/on
Log
off
off
off
off
off
off
off
on
off
on
on
Log
in
file
off/on