INSTALLATION MANUAL
–
RAVAS-
SafeLoad
29
Weight parameters
Parameter Function
Default
Settings
1
Calibration and start-
up units
1
1=kg;2=lb;3=t;4=% (3 and 4 are not
active yet)
2
smallest graduation
50 0,05;0.1;0.2;0.5;1;2;5;10;20;50;100;200;
500
3
biggest graduation
50 0,05;0.1;0.2;0.5;1;2;5;10;20;50;100;200;
500
4
number of divisions
1000
0000 to 9999 divisions
5
*
1
capacity L1:2500/L2:2250/L3:2000
H1:1800/H2:1600/H3:1400
0 to 99999
6
*
2
motion detection
0.2
off;0.1;0.2;0.3;0.4;0.5;1;2;4;8;16;32
divisions/sec.
7 filter
size
0
0,1,2,3
8
*
3
zero track filtering
band
0 0(=off);0.25;0.5;1;2;3;5;10;20
divisions/second
9
*
4
Relative zero range
positive per event
AutoZ>008/ManZ>020
0 to 100 % of span(reference point
adjusted zero)
AutoZ: automatic zero track (display
shows [AutoZ], press Enter to continue)
ManZ: manual zero (display shows
[ManZ], press Enter to continue)
10
*
4
Relative zero range
negative per event
AutoZ>002/ManZ>020
0 to 100 % of span(reference point
adjusted zero)
AutoZ: automatic zero track (display
shows [AutoZ], press Enter to continue)
ManZ: manual zero (display shows
[ManZ], press Enter to continue)
11 display
service
mode
basic
basic;count;res10
12
Power On Zero
no
yes; no
13 Zero
suppression
2
0-9
14
Horizontal
forksegments on/off
on
Off (fork segments are always on); on
(fork segments are active depending on
the load centre point of the placed load)
15
units switch active
yes
no;yes
16
Zero track timer
oilpressure
4
0 to 9 seconds
17
Treshold value fork
segments
400
0 to max. capacity (only valid if P_014 is
set to on)
18
gravity value working
area
9.812
9.750 - 9.850
19
Absolute zero range
positive (cumulative)
50
0 to 100 % of span(reference point
calibrated zero)
20
Absolute zero range
negative (cumulative)
50
0 to 100 % of span(reference point
calibrated zero)
49
underload % of FS
5
0-100
50
Peakhold timer
0
0 (peakhold inactief) 1-9 timer in sec.
51 Treshhold
value
peakhold
4
0-99 divisions
65
auto shut off
backlight
0
0;20; 40; 80; 160; 320 seconds
66 backlight
brightness
150
100/150/175/200
71 Software
versie
(installed)
x.x Fixed
value
72
Audit trail number
parameters
Changes whenever a parameter is being
changed
73
Audit trail number
calibration
Changes whenever a new calibration is