Faults and possible causes
103
10
10
Faults and possible causes
n
GEFAHR
Risk of injury and accident from omitted or inadequate trou-
bleshooting.
Delayed or incorrect repairs by unqualified persons may result in
incalculable risks with negative consequences for persons, the
machine, and the environment.
Any faults that occur must be rectified
immediately
.
Only carry out repairs yourself if you have the appropriate
qualifications.
Fault
Possible cause/action
Uneven distribution of spreading
material
Remove caked spreading material from the spreading
disc, the spreading vanes, and the outlet.
Spreading vanes worn. Replace spreading vanes.
Metering slider does not open completely. Check slider
function.
Drop point incorrectly adjusted. Correct the adjustment.
Irregular feed of spreading materi-
al to spreading disc
Check agitator and replace if necessary.
Clear blockages.
Spreading disc judders.
Make sure it is mounted tightly.
Metering slider does not open
Metering slider does not move easily. Check for smooth
slider movement, check the lever and the joints, and im-
prove if necessary.
Check tension spring.
The restrictor plate in the female hose coupling is dirty.
Power supply to actuator interrupted.
Metering slider opens too slowly
Clean restrictor plate. The restrictor is in the female hose
coupling.
Agitator not working
Check for wear.
Check the locking pins for damage and wear.