Hardware Installation
PixelStor 5000 User Manual
Rev. 1, May 2013
3-12
Figure 3-15 - PS 5000
Figure 3-16 100e/312e/324e SAS Connectors
SAS OUT - SFF-8470 Connector
SAS IN - SFF-8470 Connector
Figure 3-21 SAS Cable Connections - Shows the supported cabling configuration for PixelStor
5000 RAID system and 100e/312e/324e expansion enclosures. Start from the PixelStor 5000
chassis at the top of the diagram and connect to the first 100e/312e/324e enclosure below it.
Then add additional 100e/312e/324e enclosures.
____________________________________________________________________
Note in the single controller configuration only the bottom controller should be installed
and SAS cable connections should never be made between bottom and top controller.
The PixelStor 324e is a single controller only product should and should be connect as
such.
____________________________________________________________________
1. Each RAID controller on the PixelStor 5000 has a SAS connector marked with the
icon. Connect one end of one of the included SAS cables to SAS connector with
icon
on the PixelStor 5000.
2. Each IO module on the PixelStor 100e/312e/324e has 2 SAS connectors. One is
marked with a
icon (SAS OUT) and one is marked with a
icon (SAS IN). Connect
the other end of the SAS cable from Step 1 to the right-most module SAS connector
icon
SAS OUT always connects to
icon SAS IN.