162
D
OMINION
SX
U
SER
G
UIDE
Pre-condition
Administrator user is logged in via CLI.
6 Power Strip devices (DPX) are physically connected and configured to
DSX.
User is in power menu.
Action 1.
Enter Command to associate Port1 to Outlet1 of PowerStr1.
2.
Press Enter.
3.
Repeat steps 1 and 2 to associate Port1 with Outlet1 from each of the
other PDUs.
CLI Input
⋅
associate port 1 powerstrip PowerStr1 outlet 1
⋅
associate port 1 powerstrip PowerStr2 outlet 1
⋅
associate port 1 powerstrip PowerStr3 outlet 1
⋅
associate port 1 powerstrip PowerStr4 outlet 1
⋅
associate port 1 powerstrip PowerStr5 outlet 1
⋅
associate port 1 powerstrip PowerStr6 outlet 1
Scenario #8
Port Power Association – Edit outlet names
Pre-condition
Administrator user is logged in via CLI.
Power Strip device (DPX) is physically connected and configured to DSX
named PowerStr1.
User is in power menu.
Action 1.
Enter Command to edit outlet1 name of PowerStr1.
2.
Press Enter.
CLI Input
outlet name PowerStr1 outlet 1 newname TestName
Remove Port Power Association
Description: Power Control Menu – Remove a power outlet association from a DSX port.
Scenario #1
Remove Port Power Association
Pre-condition
Administrator user is logged in via CLI.
Power Strip device (DPX) is physically connected and configured to DSX
named PowerStr1.
User is in power menu.
Action 1.
Enter command.
2.
Press Enter.
CLI Input
Command: unassociate port 1 powerstrip PowerStr1 outlet 1
Scenario #2
Delete multiple outlets Association
Pre-condition
Administrator user is logged in via CLI.
Power Strip device (DPX) is physically connected and configured to the
DSX named PowerStr1.
User is in power menu.
Action 1.
Enter command.
2.
Press Enter.
CLI Input
Command: unassociate port 1 powerstrip PowerStr1 outlet 1,4,7
CLI Power Strip Configuration
Description: Power Control Menu
Scenario #1
Configure a DSX Port to contain a Power Strip device (the port is
previously connected to a power strip)
Pre-condition
Administrator user is logged in via CLI.
Power Strip device (DPX) is physically connected to Port1 of DSX.
Summary of Contents for DOMINION DSX-0N-E
Page 2: ...This page intentionally left blank...
Page 18: ......
Page 22: ...4 DOMINION SX USER GUIDE This page intentionally left blank...
Page 44: ...26 DOMINION SX USER GUIDE...
Page 48: ...30 DOMINION SX USER GUIDE...
Page 83: ...CHAPTER 8 SECURITY 65 Figure 59 SSL Client Certificate Screen...
Page 104: ......
Page 168: ...150 DOMINION SX USER GUIDE...
Page 172: ...154 DOMINION SX USER GUIDE...
Page 210: ...192 DOMINION SX USER GUIDE...
Page 218: ...200 DOMINION SX USER GUIDE...
Page 232: ...214 DOMINION SX USER GUIDE...