Remote control commands
R&S
®
NGU
168
User Manual 1179.2531.02 ─ 03
ARBitrary:TRIGgered[:STATe]
<state>
ARBitrary:TRIGgered[:STATe]?
Sets or queries the arbitrary trigger mode.
Parameters:
<state>
0
OFF - Trigger input is deactivated.
1
ON - Trigger input is activated.
Example:
ARB:TRIG ON
ARB:TRIG?
-> 1
Activates the Ch1 trigger mode for arbitrary function.
7.7.2
Ramp
The
VOTage:RAMP
subsystem contains the commands for configuring the ramp func-
tion for the output channels.
................................................................................. 168
[SOURce:]VOLTage:RAMP:DURation
.............................................................................. 169
[SOURce:]VOLTage:RAMP[:STATe]
<state>
[SOURce:]VOLTage:RAMP[:STATe]?
[<Channel list>]
Sets or queries the state of ramp function for the previous selected channel.
Parameters:
<state>
0
EasyRamp function is deactivated.
1
EasyRamp function is activated.
*RST:
0
Parameters for setting and query:
<Channel list>
<list>
Example:
VOLT:RAMP ON
VOLT:RAMP?
-> 1
EasyRamp function is activated
Example:
VOLT:RAMP ON, (@1)
VOLT:RAMP? (@1)
Sets and queries the state of ramp function.