Page
12
5.0
EXTERNAL WIRING TO WEATHER STATION: ( Refer to FIGS. 6 & 7)
WIRING VALVE ACCESS BOX
At the base of the Weather Station and
as near to the base as feasibly possible,
dig a hole large enough to install a
standard 18” x 24” rectangular valve box
and cover. The valve box shall
accommodate all wiring connections,
one rod of a 3-rod grounding grid,
MGP-1 grounding plate assemblies and
MSP-1 surge arrestors.
WEATHER STATION
POWER WIRING
Furnished as part of the Weather Station
is a
120VAC
to
16VAC
power
transformer. This transformer can be
located in the pedestal of a field satellite
controller that is in the near proximity of
the weather station or some other
convenient weather proof location.
Install the transformer in a
4”x 4” metal
electrical box with cover. Connect the
120VAC power wires of the transformer
to a source of 120VAC power that is not
easily turned off. To the output of the
transformer, connect a pair of UF wires,
of proper size, using “crimp-on” open
spade connectors.
clad, ground rod - one of a 3-rod
grounding grid.
NOTE !
The minimum voltage to
the transformer shall be not less than 112
volts.
Wire sizing shall be in accordance with
the chart given below.
Wire shall be Type “UF” (underground
feeder cable) with PVC insulation. The
16VAC power is used to provide
constant charging of the battery within
the weather station, through the battery
charging circuit.
WIRE SIZING CHART
WIRE SIZE
DISTANCE
(feet)*
18
500
16
800
14
1275
12
2000
10
3250
8
5100
The power wires shall be direct buried
and run over to the weather station.
Connect the 16VAC power wires to the
“
LINE
” side of an MSP-1 surge
arrestor, which shall be mounted in an
MGP-1
grounding plate assembly. The
MGP-1
grounding plate assembly shall be
securely mounted on a 5/8” dia. copper
* Transformer to Weather Station
The “
EQUIPMENT’
side of this MSP-1
surge arrestor shall be connected to
“red” and “black” wires of the 20’power
wire cable, which is furnished as part of
Summary of Contents for WS-PRO
Page 2: ......
Page 10: ...Page viii...
Page 16: ...Page 6 FIGURE 2 MAGNETIC DECLINATION FOR THE CONTIGUOUS UNITED STATE...
Page 21: ...Page 11 FIGURE 4 CONCRETE BASE DETAIL FIGURE 5 ANCHOR BOLT TEMPLATE DETAIL...
Page 24: ...Page 14 FIGURE 6 EXTERNAL WIRING DETAIL AT THE PRO SH WEATHER STATION...
Page 27: ...Page 17 FIGURE 7 EXTERNAL WIRING DETAIL AT THE PRO PH WEATHER STATION...
Page 33: ...Page 23 FIGURE 10 SOLAR PANEL INSTALLATION DETAIL...
Page 35: ...Page 25 FIGURE 11 CROSS ARM MOUNTING INSTALLATION OF 034A WIND SENSOR...
Page 48: ...Page 38 FIGURE 21 INSTALLATION AT CENTRAL COMPUTER FOR DIRECT CONNECTED WEATHER STATION...
Page 50: ...Page 40 FIGURE 22 INSTALLATION AT CENTRAL COMPUTER FOR TELEPHONE CONNECTED WEATHER STATION...
Page 73: ...Page 63 FIGURE 28 TYPICAL 3 ROD GROUNDING GRID DETAIL...
Page 75: ...Page 65 FIGURE 30 TESTING OF SOLAR RADIATION SENSOR...
Page 76: ...Page 66 FIGURE 31 TESTING OF RAIN GAGE...
Page 77: ...Page 67 FIGURE 32 TESTING OF TEMPERATURE RELATIVE HUMIDITY SENSOR...
Page 78: ...Page 68 FIGURE 33 TESTING OF AIR TEMPERATURE PROBE...