Page
55
type, on the screen then the Short
Haul Modem has a problem or the
COM port and needs to be replaced.
FIGURE 25 - TEST OF SHORT HAUL MODEM
Second:
After having determined, with
the test above that the RAD modem
at the computer is “Good” - you
can then check to see if the
communication path, between the
computer and the weather station is
“Good”.
•
Re-connect the field
communication wires to the RAD
modem output terminals, of the
RAD modem at the central
computer location.
•
At the Weather Station, disconnect
the communication wires from the
MSP-1 pipe surge arrestors and tie
the wires together as shown in
FIGURE 26 below.
•
With the Rain Bird Weather
Software, go to the Main Menu and
set the “capital lock” on the
keyboard of the computer.
•
Be sure to configure a direct connect
weather station.
•
Press a capital [
W
] from the Main
Menu screen.
•
If a security number is asked for use
[
6275
].
•
Choose a direct connect station and
the screen will go “BLANK”.
•
Assuming you have connected the
communication wires correctly at the
weather station end, as shown in
FIGURE 26 below, what you type at
the computer will be echoed back to
the computer screen. Testing in this
way will verify that the
communication wiring is “Good”.
If you so not see the characters on
the screen, that you have typed,
then you know that there is a
problem with the communication
wiring.
Summary of Contents for WS-PRO
Page 2: ......
Page 10: ...Page viii...
Page 16: ...Page 6 FIGURE 2 MAGNETIC DECLINATION FOR THE CONTIGUOUS UNITED STATE...
Page 21: ...Page 11 FIGURE 4 CONCRETE BASE DETAIL FIGURE 5 ANCHOR BOLT TEMPLATE DETAIL...
Page 24: ...Page 14 FIGURE 6 EXTERNAL WIRING DETAIL AT THE PRO SH WEATHER STATION...
Page 27: ...Page 17 FIGURE 7 EXTERNAL WIRING DETAIL AT THE PRO PH WEATHER STATION...
Page 33: ...Page 23 FIGURE 10 SOLAR PANEL INSTALLATION DETAIL...
Page 35: ...Page 25 FIGURE 11 CROSS ARM MOUNTING INSTALLATION OF 034A WIND SENSOR...
Page 48: ...Page 38 FIGURE 21 INSTALLATION AT CENTRAL COMPUTER FOR DIRECT CONNECTED WEATHER STATION...
Page 50: ...Page 40 FIGURE 22 INSTALLATION AT CENTRAL COMPUTER FOR TELEPHONE CONNECTED WEATHER STATION...
Page 73: ...Page 63 FIGURE 28 TYPICAL 3 ROD GROUNDING GRID DETAIL...
Page 75: ...Page 65 FIGURE 30 TESTING OF SOLAR RADIATION SENSOR...
Page 76: ...Page 66 FIGURE 31 TESTING OF RAIN GAGE...
Page 77: ...Page 67 FIGURE 32 TESTING OF TEMPERATURE RELATIVE HUMIDITY SENSOR...
Page 78: ...Page 68 FIGURE 33 TESTING OF AIR TEMPERATURE PROBE...