Page
26
Refer to FIGURE 12 below:
With the Sensor Cross-Arm securely
installed to the Enclosure you are ready
to install the 034A Wind Sensor
instrument. The wind vane is oriented
after the datalogger has been
programmed and the location of True
North has been determined. Orientation
is most easily done with two people,
one to aim and adjust the sensor, while
the other observes the wind direction
displayed by CR10KD Keyboard
Display or a laptop PC computer.
Remove the aligning screw from the
base of the 034A wind sensor unit.
Place the 034A wind sensor into the
mounting shaft, that is clamped to the
end of the sensor cross-arm by means of
a U-Bolt clamp.
(The short, black mounting shaft,
included with the 034A wind sensor will
NOT be used).
Secure the 034A wind sensor in the
mounting shaft, by aligning the threaded
hole in the wind sensor with the hole in
the side of the mounting shaft, and re-
installing the aligning screw.
Next loosen the set screw in the top of
the 034A wind sensor (the set screw
opposite the one securing the wind
direction point). Place the end of the
wind vane into the hole. Properly orient
the vane to be in a true vertical position
and secure it by tightening the set screw.
Attach the wind sensor cable connector
to the connector on the 034A wind
sensor.
Without allowing the mounting shaft for
the 034A wind sensor to “slip down” (it
may be a good idea to mark the position
of the U-Bolt on the shaft so that you
can correctly position it should is “slip”)
slightly loosen the nuts of the “U-Bolt”
clamp of the mounting shaft - just
enough so you can rotate the mounting
shaft but not allow the shaft to “slip
down”.
Establish a reference point on the
horizon for True North.
Sighting down the instrument center
line, aim the counter weight at True
North. Display input location #8 for
wind direction, using the *6 Mode of
the datalogger.
While holding the wind vane position,
slowly rotate the sensor base/mounting
shaft until the datalogger indicates 0
degrees. Securely tighten the clamp
nuts.
REFER TO NEXT PAGE FOR FIGURE 12
Summary of Contents for WS-PRO
Page 2: ......
Page 10: ...Page viii...
Page 16: ...Page 6 FIGURE 2 MAGNETIC DECLINATION FOR THE CONTIGUOUS UNITED STATE...
Page 21: ...Page 11 FIGURE 4 CONCRETE BASE DETAIL FIGURE 5 ANCHOR BOLT TEMPLATE DETAIL...
Page 24: ...Page 14 FIGURE 6 EXTERNAL WIRING DETAIL AT THE PRO SH WEATHER STATION...
Page 27: ...Page 17 FIGURE 7 EXTERNAL WIRING DETAIL AT THE PRO PH WEATHER STATION...
Page 33: ...Page 23 FIGURE 10 SOLAR PANEL INSTALLATION DETAIL...
Page 35: ...Page 25 FIGURE 11 CROSS ARM MOUNTING INSTALLATION OF 034A WIND SENSOR...
Page 48: ...Page 38 FIGURE 21 INSTALLATION AT CENTRAL COMPUTER FOR DIRECT CONNECTED WEATHER STATION...
Page 50: ...Page 40 FIGURE 22 INSTALLATION AT CENTRAL COMPUTER FOR TELEPHONE CONNECTED WEATHER STATION...
Page 73: ...Page 63 FIGURE 28 TYPICAL 3 ROD GROUNDING GRID DETAIL...
Page 75: ...Page 65 FIGURE 30 TESTING OF SOLAR RADIATION SENSOR...
Page 76: ...Page 66 FIGURE 31 TESTING OF RAIN GAGE...
Page 77: ...Page 67 FIGURE 32 TESTING OF TEMPERATURE RELATIVE HUMIDITY SENSOR...
Page 78: ...Page 68 FIGURE 33 TESTING OF AIR TEMPERATURE PROBE...